Aortic valve reconstruction using autologous pericardium (Ozaki procedure) for active infective endocarditis: a case report |
| |
Authors: | Kimiaki Okada Yoshito Inoue Hirofumi Haida Satoru Suzuki |
| |
Institution: | 1.Department of Cardiovascular Surgery,Tokai University,Isehara city,Japan;2.Department of Cardiovascular Surgery,Hiratsuka City Hospital,Kanagawa,Japan |
| |
Abstract: | Approximately one-third of patients with infective endocarditis require surgical treatment, but the ideal procedure that prevents infection ensures long durability and maintains quality of life remains unclear. A 21-year-old man who was diagnosed with aortic active infective endocarditis was referred to our hospital for surgical treatment. Echocardiography showed bicuspid aortic valve, severe aortic regurgitation, a large vegetation, and a paravalvular abscess. We planned to perform elective surgical treatment after antibiotic therapy; however, progression to heart failure required urgent operation. Aortic valve reconstruction (AVr) using autologous pericardium was performed. Perioperative and postoperative courses were uneventful. No recurrence of infection or adverse events were observed 4 years postoperatively. Considering prosthetic valve infection and redo operation, AVr may be considered among young patients. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|