首页 | 本学科首页   官方微博 | 高级检索  
     

加校正因子的主成分自身对照法测定马来酸依那普利片有关物质
引用本文:魏凯,李欣. 加校正因子的主成分自身对照法测定马来酸依那普利片有关物质[J]. 中国药品标准, 2021, 22(1): 26-31
作者姓名:魏凯  李欣
作者单位:黑龙江天宏药业股份有限公司;哈尔滨市食品药品检验中心
摘    要:目的:建立加校正因子的主成分自身对照法测定马来酸依那普利片有关物质的含量.方法:用辛烷基硅烷键合硅胶为填充剂,以磷酸盐缓冲溶液(0.01 mol · L-1磷酸二氢钾溶液,用磷酸调pH值为2.2)-乙腈(75:25)为流动相;检测波长215 nm;柱温为50 ℃.测定依那普利拉(杂质Ⅰ)和依那普利双酮(杂质Ⅱ)相对于依...

关 键 词:马来酸依那普利片  有关物质  校正因子  高效液相色谱法

The Method of Main Component Self-Control Corrected with Calibration Factor Was Used for Determination of Related Substances in Enalapril Maleate Tablets
WEI Kai,LI Xin. The Method of Main Component Self-Control Corrected with Calibration Factor Was Used for Determination of Related Substances in Enalapril Maleate Tablets[J]. , 2021, 22(1): 26-31
Authors:WEI Kai  LI Xin
Affiliation:(Heilongjiang Timehome Pharmaceutical Co.,Ltd.,Harbin 150025,China;Harbin Institute for Food and Drug Control,Harbin 150001,China)
Abstract:Objective:To establish the method of main component self-control corrected with calibration factor to determine the related substances in Enalapril Maleate Tablets.Methods:The test was performed in octyl silane bonded silica gel column under the elution of phosphate buffer solution(adjusting pH to 2.2 with phosphoric acid)-acetonitrile(75∶25).The column temperature was 50℃,and the detection wavelength was 215 nm.The calibration factors of Enalaprilat(impurityⅠ)and enalapril diketopiperazine(impurityⅡ)relative to enalapril were determined,then the quantitative analysis of the impurities was made.Results:The resolutions between Enalapril and the adjacent peaks as well as the known impurities all met the requirements.The calibration curves of Enalapril and impuritiesⅠ,Ⅱwere linear in the range of 0.5-30μg·mL-1(r>0.999).The calibration factors of impuritiesⅠandⅡwere 0.71 and 0.92,respectively.The main component self-control method with calibration factor should be used for quantitative analysis of impurityⅠ.There were no significant differences between the results determined by the external standard method and the main component self-control method with calibration factor.Conclusion:The established method is simple and accurate,and it is suitable for the determination of related substances in Enalapril Maleate tablets.
Keywords:Enalapril Maleate Tablets  related substances  relative calibration factor  HPLC
本文献已被 维普 等数据库收录!
点击此处可从《中国药品标准》浏览原始摘要信息
点击此处可从《中国药品标准》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏