首页 | 本学科首页   官方微博 | 高级检索  
     

2017-2019年我国介入放射学工作人员眼晶状体剂量水平与分析
引用本文:李梦雪,邓君,郝述霞,范胜男,苏垠平,刘建香,刘晓惠,孙全富. 2017-2019年我国介入放射学工作人员眼晶状体剂量水平与分析[J]. 中华放射医学与防护杂志, 2021, 41(2): 92-98
作者姓名:李梦雪  邓君  郝述霞  范胜男  苏垠平  刘建香  刘晓惠  孙全富
作者单位:中国疾病预防控制中心辐射防护与核安全医学所 辐射防护与核应急中国疾病预防控制中心重点实验室, 北京 100088
摘    要:目的 调查2017-2019年我国介入放射学工作人员眼晶状体辐射剂量水平,掌握我国介入放射工作人员眼晶状体剂量水平现状.方法 通过国家个人剂量登记系统,采集我国28个省份介入放射学工作人员眼晶状体剂量监测数据,监测部位为左眼、评估指标为个人剂量当量Hp(3)、监测方法为热释光剂量计.分别运用Mann-Whitney U...

关 键 词:介入放射学  职业人群  眼晶状体  年当量剂量  Hp(3)
收稿时间:2020-10-16

Results and analyses of occupational eye lens doses in interventional radiology in China (2017-2019)
Li Mengxue,Deng Jun,Hao Shuxi,Fan Shengnan,Su Yinping,Liu Jianxiang,Liu Xiaohui,Sun Quanfu. Results and analyses of occupational eye lens doses in interventional radiology in China (2017-2019)[J]. Chinese Journal of Radiological Medicine and Protection, 2021, 41(2): 92-98
Authors:Li Mengxue  Deng Jun  Hao Shuxi  Fan Shengnan  Su Yinping  Liu Jianxiang  Liu Xiaohui  Sun Quanfu
Affiliation:Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China
Abstract:Objective To investigate the levels of dose to eye lens of interventional radiology workers in China from 2017 to 2019. Methods The monitoring data on eye lens doses to the interventional radiology workers in 28 provinces across the country were collected from National Individual Dose Registry. Monitoring was carried out using TLDs on their left eyes and evaluated in terms of the personal dose equivalent Hp(3 ). By using Mann-Whitney U test and Kruskal-Wallis H test, statistical analyses were made of the average annual lens doses to interventional radiology workers in the hospitals of different types at different levels for different years. Results From 2017 to 2019, the data on eye lens doses to 2 981 interventional radiology workers were collected, with doses ranging from below the minimum detectable level (MDL) to 64.48 mSv, the average annual eye dose of 1.38 mSv, and the annual doses incurred by 0.97% monitored workers exceeding the recently recommended dose limits, 20 mSv per year. The average annual lens dose monitored in general hospitals and in cancer hospitals were 1.33 and 1.77 mSv, respectively, without statistically significant difference (P>0.05 ). The average annual lens dose in tertiary hospitals was 1.39 mSv, significantly higher than that in secondary hospitals where the value was 1.16 mSv (Z=2.894,P<0.05 ). Conclusions The estimated annual eye lens doses to the interventional radiology workers during 2017-2019 were in accordance with the current national standard GB 18871-2002, but with a few exceptions exceeding the current international standards. This means that there exists, to a certain degree, a potential risk for the eye lens in this work category to exceed the international limits. It is suggested to continue in effort to enhance the monitoring of eye lens dose for these workers and to increase risk awareness, and take effective protective measures so as to lower the level of eye lens doses.
Keywords:Interventional radiology  Occupational population  Eye lens  Annual equivalent dose  Hp(3)
本文献已被 维普 等数据库收录!
点击此处可从《中华放射医学与防护杂志》浏览原始摘要信息
点击此处可从《中华放射医学与防护杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号