Anatomic and histopathologic findings following a failed ahmed glaucoma valve device
Authors:Ayyala R S  Layden W E  Slonim C B  Margo C E
Affiliation:Department of Ophthalmology, Tulane University Medical Center, New Orleans, Louisiana 70124, USA. rsayyala@hotmail.com
Abstract:Ahmed glaucoma valve implant (AGV) is one of the more commonly used implants in difficult glaucomas. The histology of a functioning bleb following AGV implantation and its anatomic relationship to the optic nerve when placed in the superionasal quadrant has been described. We report the histology of a failed bleb and the anatomic relationship between the optic nerve and the AGV end-plate when placed 9 mm from the limbus in a patient with neovascular glaucoma.