首页 | 本学科首页   官方微博 | 高级检索  
     

基于Mask R-CNN的超声图像中胎儿头围测量方法
引用本文:李宗桂,张俊华,梅礼晔. 基于Mask R-CNN的超声图像中胎儿头围测量方法[J]. 中国生物医学工程学报, 2021, 40(1): 12-18. DOI: 10.3969/j.issn.0258-8021.2021.01.02
作者姓名:李宗桂  张俊华  梅礼晔
作者单位:(云南大学信息学院,昆明 650500)
基金项目:国家自然科学基金(61841112)。
摘    要:胎儿头围是产前超声检查中评价胎儿生长发育最重要的生物特征之一,但手工测量耗时费力且存在操作者的误差.对此,根据超声图像中胎儿头部接近椭圆形状的特征,提出头围测量损失函数.在Mask R-CNN的分割分支后,利用ElliFit算法对分割掩膜进行椭圆拟合,用Ramanujan公式计算拟合椭圆周长作为头围测量值,将头围真实值...

关 键 词:超声图像  Mask R-CNN  椭圆拟合  胎儿头围测量  损失函数
收稿时间:2019-12-10

Method for Measuring Fetal Head Circumference in Ultrasound Images Based on Mask R-CNN
Li Zonggui,Zhang Junhua,Mei Liye. Method for Measuring Fetal Head Circumference in Ultrasound Images Based on Mask R-CNN[J]. Chinese Journal of Biomedical Engineering, 2021, 40(1): 12-18. DOI: 10.3969/j.issn.0258-8021.2021.01.02
Authors:Li Zonggui  Zhang Junhua  Mei Liye
Affiliation:(School of Information, Yunnan University, Kunming 650500, China)
Abstract:Fetal head circumference is one of the most important biological characteristics in prenatal ultrasound evaluation of fetal growth and development. However,manual measurement is time-consuming and laborconsuming and may have errors by the operator. According to the feature of fetal head close to ellipse shape in ultrasound image,the head circumference measurement loss function was proposed in this paper. After the segmentation branch of Mask R-CNN,ElliFit algorithm was used to fit the ellipse of the segmentation mask.Ramanujan formula was used to calculate the fitting ellipse circumference as the measurement value of the head circumference. The mean square error of the real value of the head circumference and the measurement value was added into the original loss function as head circumference measurement loss function to allow the training process of the model to be closely related to the measurement task. By this way the measurement accuracy and speed was improved. One hundred and ninety ultrasound images of fetal head were tested. Dice’s coefficient was 96. 89% ±1. 01%,and the measurement error was(0. 33±1. 54)mm. The average processing time of one ultrasound image was 0. 33 s. Compared with the traditional manual measurement method or the current machine learning methods,the proposed method improved the speed between 1. 13 seconds and 16. 87 seconds,and improved the accuracy between 0. 21 mm and 1. 68 mm. The results showed that the improved Mask R-CNN increased the efficiency of doctors in measuring fetal head circumference,which met the clinical needs.
Keywords:ultrasound image  Mask R-CNN  ellipse fitting  fetal head circumference measurement  loss function
本文献已被 维普 等数据库收录!
点击此处可从《中国生物医学工程学报》浏览原始摘要信息
点击此处可从《中国生物医学工程学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号