Implementation of hazard analysis critical control point in jameed production
Authors:Al-Saed A K  Al-Groum R M  Al-Dabbas M M
Affiliation:Department of Nutrition and Food Technology, University of Jordan, Amman, Jordan.
Abstract:The average of standard plate count and coliforms, Staphylococcus aureus and Salmonella counts for three home-made jameed samples, a traditional fermented dairy product, before applying hazard analysis critical control point system were 2.1?×?10(3), 8.9?×?10(1), 4?×?10(1) and less than 10?cfu/g, respectively. The developed hazard analysis critical control point plan resulted in identifying ten critical control points in the flow chart of jameed production. The critical control points included fresh milk receiving, pasteurization, addition of starter, water and salt, straining, personnel hygiene, drying and packaging. After applying hazard analysis critical control point system, there was significant improvement in the microbiological quality of the home-made jameed. The standard plate count was reduced to 3.1?×?10(2)?cfu/g whereas coliform and Staphylococcus aureus counts were less than 10?cfu/g and Salmonella was not detected. Sensory evaluation results of color and flavor of sauce prepared from jameed showed a significant increase in the average scores given after hazard analysis critical control point application.