首页 | 本学科首页   官方微博 | 高级检索  
     


Decreased sensitivity of early imaging with In-111 oxine-labeled leukocytes in detection of occult infection: concise communication
Authors:F L Datz  J Jacobs  W Baker  W Landrum  N Alazraki  A Taylor
Abstract:Imaging with leukocytes labeled with indium-111 oxine is a sensitive technique for detecting sites of occult infection. Traditionally, imaging is performed 24 hr after injection. We undertook a prospective study of 35 patients (40 studies) with possible occult infection to see whether a 24-hr delay in imaging is really necessary. Patients were imaged at 1-4 hr and again at 24 hr after injection. The early images had a sensitivity of only 33%, compared with 95% for the 24-hr images. Of the seven studies that were positive on both early and delayed images, 71% had more intense uptake at 24 hr. There were no false-positive early images. We conclude that imaging 1-4 hr after injection with In-111 oxine-labeled leukocytes has a low sensitivity for detecting occult infection. However, a positive early image is specific for a site of infection.
Keywords:
本文献已被 PubMed 等数据库收录!