Intrarenal kinetics of Gd-DOTA in sequential MRI in rabbits. Reproducibility study
Authors:N Grenier  J L Barat  D Ducassou  J Broussin
Abstract:Ten normal rabbits and seven rabbits with experimental acute renal failure by tubular necrosis were studied with dynamic MR to evaluate the reproducibility of intrarenal kinetics of Gd-DOTA. Sequential spin-echo sequences with short TR (200 msec)/TE (26 msec) were used yielding a 29 sec acquisition time. A usual semi-quantitative analysis of intrarenal contrast demonstrated the reproducibility of some phases of the dynamic sequence in particular a drop in the signal within inner medulla between the third and the fourth minute after infusion. This effect, related to a high concentration of Gd-DOTA within the tubules was observed in 9 over 10 normal rabbits and in none of the rabbits with acute renal failure. The quantitative analysis calculation was based on relative signal intensity and contrast-to-noise ratio from the absolute signal intensity measure on regions-of-interest (ROI) on the cortex, outer medulla and inner medulla. No reproducibility of the variations with time of these parameters could be assessed. A great number of factors of variations or error, mainly during the measurements of signal intensity with ROI, could explain this lack of reproducibility. At the present, dynamic MR is therefore not able to quantitatively evaluate the renal function. Only a semi-quantitative estimation of tubular concentration can be deduced.