首页 | 本学科首页   官方微博 | 高级检索  
     


Combined use of the high heparin step and optical density to optimize diagnostic sensitivity and specificity of an anti-PF4/heparin enzyme-immunoassay
Authors:Althaus Karina  Strobel Ulrike  Warkentin Theodore E  Greinacher Andreas
Affiliation:
  • a Institut für Immunologie und Transfusionsmedizin, Ernst-Moritz-Arndt Universität Greifswald, Germany
  • b Department of Pathology and Molecular Medicine, McMaster University, Hamilton, Ontario, Canada
  • Abstract:

    Background

    IgG-specific anti-PF4/heparin enzyme-immunoassays (EIAs) are sensitive but not specific for platelet-activating antibodies, the cause of heparin-induced thrombocytopenia (HIT). Two features of EIA reactivity predict for presence of HIT antibodies - the magnitude of a positive result (in optical density [OD] units) and the inhibition of reactivity at high heparin concentrations - but their combined utility remains uncertain.

    Objective

    To determine for an IgG-specific EIA how the OD values of a positive reaction and its inhibition by high heparin can be optimally combined.

    Methods

    We screened 1,000 consecutive patients with suspected HIT using an IgG-specific PF4/heparin in-house EIA with and without high heparin (100 IU/mL); and by the heparin-induced platelet activation test.

    Results

    Platelet-activating antibodies were rarely detected (< 0.2%) when the IgG-specific EIA was negative at the conventional cut-off (OD, 0.5). However, an OD cut-off of 1.0 resulted in an unacceptable loss of sensitivity (14/83 = 17%) for detecting platelet-activating antibodies. The high heparin step increased specificity for platelet-activating antibodies from 72% to 89% without loss of sensitivity when applied to weak-positive sera (OD ≤ 1.0). However, decreased sensitivity was observed with strong-positive sera (OD > 1.0): 11/69 such sera (16%) that did not show > 40% inhibition by high heparin nevertheless contained platelet-activating antibodies.

    Conclusion

    Specificity of an IgG-specific EIA for detecting platelet-activating antibodies can be optimized by applying the high heparin inhibition step to weak-positive reactions (0.5- ≤ 1.0 OD). However, applying the high heparin inhibition step to strong-positive reactions (> 1.0 OD) in our in-house assay risks falsely classifying a serum as negative for platelet-activating antibodies.
    Keywords:Heparin-induced thrombocytopenia   HIT   laboratory testing   heparin   PF4