Prospective comparison of echocardiographic atrioventricular delay optimization methods for cardiac resynchronization therapy
Authors:Jeffrey E Kerlan MD  Navinder S Sawhney MD  Alan D Waggoner MHS  Mohit K Chawla MD  Sanjeev Garhwal MD  Judy L Osborn RN  BSN  Mitchell N Faddis MD  PhD
Institution:Cardiovascular Division, Washington University School of Medicine, St. Louis, Missouri 63110, USA. jkerlan@im.wustl.edu
Abstract:BACKGROUND: Atrioventricular (AV) delay optimization can be an important determinant of the response to cardiac resynchronization therapy (CRT) in patients with medically refractory heart failure and a ventricular conduction delay. OBJECTIVES: The purpose of this study was to compare two Doppler echocardiographic methods of AV delay optimization after CRT. METHODS: Forty consecutive patients (age 59 +/- 12 years) with severe heart failure, New York Heart Association class 3.1 +/- 0.4, QRS duration 177 +/- 23 ms, and left ventricular ejection fraction 26% +/- 6% referred for CRT were studied using two-dimensional Doppler echocardiography. In each patient, the acute improvement in stroke volume with CRT in response to two methods of AV delay optimization was compared. In the first method, the AV delay that produced the largest increase in the aortic velocity time integral (VTI) derived from continuous-wave Doppler (aortic VTI method) was measured. In the second method, the AV delay that optimized the timing of mitral valve closure to occur simultaneously with the onset of left ventricular systole was calculated from pulsed Doppler mitral waveforms at a short and long AV delay interval (mitral inflow method). RESULTS: The optimized AV delay determined by the aortic VTI method resulted in an increase in aortic VTI of 19% +/- 13% compared with an increase of 12% +/- 12% by the mitral inflow method (P <.001). The optimized AV delay by the aortic VTI method was significantly longer than the optimized AV delay calculated from the mitral inflow method (119 +/- 34 ms vs 95 +/- 24 ms, P <.001). There was no correlation in the AV delay determined by the two methods (r = 0.03). CONCLUSION: AV delay optimization by Doppler echocardiography for patients with severe heart failure treated with a CRT device yields a greater systolic improvement when guided by the aortic VTI method compared with the mitral inflow method.
Keywords:Heart failure  Cardiac resynchronization therapy  Doppler echocardiography
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号