Evaluation of different methods to detect methicillin resistance in small-colony variants of Staphylococcus aureus |
| |
Authors: | Kipp Frank Becker Karsten Peters Georg von Eiff Christof |
| |
Affiliation: | Institute of Medical Microbiology, University Hospital of Münster, 48149 Münster, Germany. |
| |
Abstract: | To evaluate different methods for their abilities to detect methicillin resistance in small-colony variants (SCVs) of Staphylococcus aureus, 11 different methicillin-resistant S. aureus (MRSA) clones with the SCV phenotype were used in this study. The slow growth of SCVs often makes testing by disk diffusion or by automated methods invalid. Only detection of the mecA gene by PCR and the MRSA-Screen latex agglutination test using a higher colony number were shown to be reliable methods to rapidly detect methicillin resistance in these variants. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|