Biocompatibility pattern of a bicarbonate/lactate-buffered peritoneal dialysis fluid in APD: a prospective, randomized study.
Authors:Andreas Fusshoeller  Marcus Plail  Bernd Grabensee  Joerg Plum
Affiliation:Department of Nephrology and Rheumatology, Heinrich Heine-University of Düsseldorf, Moorenstrasse 5, 40225 Duesseldorf, Germany. Andreas.Fusshoeller@uni-duesseldorf.de
Abstract:BACKGROUND: In chronic ambulatory peritoneal dialysis, bicarbonate-buffered fluids, with their neutral pH and less advanced glycosylation end-products (AGE) and glucose degradation products (GDP), have better biocompatibility than conventional peritoneal dialysis (PD) solutions. That difference may be more beneficial in automated peritoneal dialysis (APD), due to its more frequent exchanges and longer contact times with fresh dialysate. We performed a prospective, randomized study in APD patients to compare the biocompatibility of conventional and bicarbonate/lactate-buffered PD fluids. METHODS: We randomized 14 APD patients to have APD with either conventional or bicarbonate/lactate-based fluids. After 6 months, both groups changed to the other solution. The overall observation period was 12 months. After 1 and 5 months and again after 7 and 11 months, phagocytotic and respiratory burst capacities of effluent peritoneal macrophages were determined. Plasma interleukin (IL)-6 and C-reactive protein (CRP) as well as effluent IL-6, CRP, transforming growth factor (TGF)-beta 1, AGE and CA125 concentrations were measured. Inflow pain was quantified using a patient questionnaire. RESULTS: Respiratory burst capacity remained unchanged and phagocytotic activity increased significantly during APD (P<0.001) with the bicarbonate/lactate fluid. Effluent IL-6 release was significantly lower than with the lactate fluid (P<0.05). While in the effluent TGF-beta 1 was unaffected, AGE concentration was lower after bicarbonate/lactate treatment (P<0.05). Effluent CA125 concentration, an indicator of mesothelial cell integrity, was higher (P<0.05) in neutral effluents. Finally, patients' inflow pain diminished (P = 0.05) when using the neutral fluid. CONCLUSIONS: The use of a neutral PD fluid in APD improved patients' inflow pain as well as biocompatibility parameters reflecting enhanced phagocytotic activity of peritoneal macrophages, reduced constitutive inflammatory stimulation (IL-6), reduced AGE accumulation in the peritoneal cavity and better preservation of the mesothelial cell integrity. From the biocompatibility point of view, a neutral fluid with low GDP content can be recommended as the primary choice for APD.
Keywords:advanced glycosylation end-products   automated peritoneal dialysis   bicarbonate   biocompatibility   glucose degradation products   interleukin-6
本文献已被 Oxford 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号