Quantitation of renal uptake of technetium-99m DMSA using SPECT |
| |
Authors: | D Groshar A Frankel G Iosilevsky O Israel B Moskovitz D R Levin D Front |
| |
Affiliation: | Division of Nuclear Medicine, Rebecca Sieff Government Hospital, Safed, Israel. |
| |
Abstract: | Quantitative single photon emission computed tomography (SPECT) methodology based on calibration with kidney phantoms has been applied for the assessment of renal uptake of [99mTc]DMSA in 25 normals; 16 patients with a single normal kidney; 30 patients with unilateral nephropathy; and 17 patients with bilateral nephropathy. An excellent correlation (r = 0.99, s.e.e. = 152) was found between SPECT measured concentration and actual concentration in kidney phantoms. Kidney uptake at 6 hr after injection in normals was 20.0% +/- 4.6% for the left and 20.8% +/- 4.4% for the right. Patients with unilateral nephropathy had a statistically significant (p less than 0.001) low uptake in the diseased kidney (7.0% +/- 4.7%), but the contralateral kidney uptake did not differ from the normal group (20.0% +/- 7.0%). The method was especially useful in patients with bilateral nephropathy. Significantly (p less than 0.001) decreased uptake was found in both kidneys (5.1% +/- 3.4% for the left and 6.7% +/- 4.2% for the right). The total kidney uptake (right and left) in this group showed to be inversely correlated (r = 0.83) with serum creatinine. The uptake of [99mTc]DMSA in single normal kidney was higher (p less than 0.001) than in a normal kidney (34.7% +/- 11.9%), however, it was lower than the total absolute uptake (RT + LT = 41.5% +/- 8.8%) in the normal group. The results indicate that SPECT is a reliable and reproducible technique to quantitate absolute kidney uptake of [99mTc]DMSA. |
| |