首页 | 本学科首页   官方微博 | 高级检索  
     


Light-emitting diode therapy (LEDT) improves functional capacity in rats with heart failure
Authors:Lucas Capalonga,Marlus Karsten,Vítor Scotta Hentschke,Douglas Dalcin Rossato,Maurício Pinto Dornelles,Anelise Sonza,Vanderlei Salvador Bagnato,Cleber Ferraresi,Nivaldo Antonio Parizotto,Pedro Dal Lago
Affiliation:1.Laboratory of Experimental Physiology,Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA),Porto Alegre,Brazil;2.Post-Graduation Program in Rehabilitation Sciences,UFCSPA,Porto Alegre,Brazil;3.Post-Graduation Program in Health Sciences,UFCSPA,Porto Alegre,Brazil;4.Centro Universitário Franciscano,Santa Maria,Brazil;5.Physics Institute of Sao Carlos,Universidade de S?o Paulo (USP),S?o Carlos,Brazil;6.Laboratory of Electrothermophototherapy, Department of Physical Therapy,Universidade Federal de S?o Carlos (UFSCar),S?o Carlos,Brazil;7.Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School,Harvard University,Boston,USA;8.Programa de Pós-Gradua??o em Ciências da Reabilita??o (PPG-CR),Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA),Porto Alegre,Brazil
Abstract:The syndrome of heart failure (HF) promotes central and peripheral dysfunctions that result in functional capacity decrease, leading to fatigue, dyspnea, and exercise intolerance. The use of light-emitting diode therapy (LEDT) has shown good results reducing fatigue and exercise intolerance, when applied on skeletal muscles before or after exercises. Thereby, the aim of this study was to compare the effects of LEDT on functional capacity, aerobic power, and hemodynamic function in HF rats. Male Wistar rats (230–260 g) were randomly allocated into three experimental groups: Sham (n?=?6), Control-HF (n?=?4), and LEDT-HF (n?=?6). The animals were subjected to an exercise performance test (ET) with gas analysis coupled in a metabolic chamber for rats performed two times (6 and 14 weeks after myocardial infarction). On the day after the baseline aerobic capacity test, the animals were submitted during 8 weeks to the phototherapy protocol, five times/week, 60 s of irradiation, 6 J delivered per muscle group. Statistical analysis was performed by one- and two-way ANOVAs with repeated measures and Student-Newman-Keuls post hoc tests (p?≤?0.05). Comparing the percentage difference (Δ) between baseline and the final ET, there was no significant difference for the VO2max variable considering all groups. However, Sham and LEDT-HF groups showed higher relative values than the Control-HF group, respectively, for distance covered (27.7 and 32.5 %), time of exercise test (17.7 and 20.5 %), and speed (13.6 and 12.2 %). In conclusion, LEDT was able to increase the functional capacity evaluated by distance covered, time, and speed of exercise in rats with HF.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号