首页 | 本学科首页   官方微博 | 高级检索  
检索        


Efficacy of everolimus eluting stent implantation in patients with calcified coronary culprit lesions: Two‐year angiographic and three‐year clinical results from the SPIRIT II study
Authors:Yoshinobu Onuma MD  Shuzou Tanimoto MD  Peter Ruygrok MD  Jörg Neuzner MD  Jan J Piek MD  PhD  Ashok Seth MD  Joachim J Schofer MD  Gert Richardt MD  Marcus Wiemer MD  Didier Carrié MD  Leif Thuesen MD  Cecile Dorange MSc  Karine Miquel‐Hebert PhD  Susan Veldhof RN  Patrick W Serruys MD  PhD
Institution:1. Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands;2. Green Lane Cardiovascular Service, Auckland, New Zealand;3. Klinikum Kassel, Kassel, Germany;4. Academisch Medisch Centrum, Amsterdam, The Netherlands;5. Escorts Heart Institute and Research Centre, New Delhi, India;6. Kardiologische Gemeinschaftspraxis, Hamburg, Germany;7. Segeberger Kliniken, Bad Segeberg, Germany;8. Herzzentrum, Bad Oeynhausen, Germany;9. CHU, Rangueil, Toulouse, France;10. Skejby Sygehus, Aarhus, Denmark;11. Abbott Vascular, Diegem, Belgium
Abstract:Background : Little is known about the impact of treatment with drug‐eluting stents (DES) on calcified coronary lesions. This analysis sought to assess the safety and efficacy of the XIENCE V everolimus‐eluting stent (EES) in patients with calcified or noncalcified culprit lesions. Methods : The study population consisted of 212 patients with 247 lesions, who were treated with EES alone. Target lesions were angiographically classified as none/mild, moderate, or severe grades of calcification. The population was divided into two groups: those with at least one target lesion moderately or severely calcified (the calcified group: 68 patients with 75 calcified lesions) and those with all target lesions having mild or no calcification (the noncalcified group: 144 patients). Six‐month and 2‐year angiographic follow‐up and clinical follow‐up up to 3 years were completed. Results : The baseline characteristics were not significantly different between both groups. When compared with the noncalcified group, the calcified group had significantly higher rates of 6‐month in‐stent angiographic binary restenosis (ABR, 4.3% vs. 0%, P = 0.03) and ischemia‐driven target lesion revascularization (ID‐TLR, 5.9% vs. 0%, P = 0.01), resulting in numerically higher major cardiac adverse events (MACE, 5.9% vs. 1.4%, P = 0.09). At 2 years, when compared with the noncalcified group, the calcified group presented higher in‐stent ABR (7.4% vs. 0%, P = 0.08) and ID‐TLR (7.8% vs. 1.5%, P = 0.03), resulting in numerically higher MACE (10.9% vs. 4.4%, P = 0.12). At 3 years, ID‐TLR tended to be higher in the calcified group than in the noncalcified group (8.6% vs. 2.4%, P = 0.11), resulting in numerically higher MACE (12.1% vs. 4.7%, P = 0.12). Conclusions: The MACE rates in patients treated with EES for calcified lesions were higher than in those for noncalcified lesions, but remained lower than the results of previously reported stent studies. EES implantation in patients with calcified culprit lesions was safe and associated with favorable reduction of restenosis and repeat revascularization. © 2010 Wiley‐Liss, Inc.
Keywords:calcification  everolimus  stents  coronary artery disease  revascularization