首页 | 本学科首页   官方微博 | 高级检索  
     

99锝m N-2-巯基吡啶-N-氧化物与99锝m-甲氧基异丁基异腈对犬急性心肌梗死模型的对照研究
引用本文:沙非,温晓斐,卜丽红,李任飞,张同,金钟男,申宝忠. 99锝m N-2-巯基吡啶-N-氧化物与99锝m-甲氧基异丁基异腈对犬急性心肌梗死模型的对照研究[J]. 中华放射学杂志, 2010, 45(12): 392-398. DOI: 10.3760/cma.j.issn.1005-1201.2011.04.016
作者姓名:沙非  温晓斐  卜丽红  李任飞  张同  金钟男  申宝忠
作者单位:哈尔滨医科大学第四临床医学院医学影像科,150001;
基金项目:科技部国际科学合作项目国家自然科学基金资助项目哈尔滨市科技攻关计划项目中国博士后科学基金特别资助项目第42批中国博士后科学基金面上资助项目黑龙江省卫生厅资助项目教育部春晖计划合作项目黑龙江省教育厅基金资助项目黑龙江省青年基金资助项目
摘    要:Objective The purpose of the present study is to compare the pharmacokinetic and biodistribution properties of 99Tcm N-mercaptopyridine-N-oxide (99 Tcm N-MPO) with 99 Tcm-sestamibi (99 Tcm-MIBI) in normal dogs, and to investigate the potential of 99TcmN-MPO as a myocardial perfusion agent in canines with acute myocardial infarction. Methods Twelve healthy mongrel dogs were injected intravenously with 99TcmN-MPO (n = 6) or 99Tcm-MIBI (n = 6). Tracer kinetics in body fluids were determined by collecting blood of 1 ml via a femoral vein catheter at 30 s, 1,2,3,4,5, 10, 20, 30, 40, 60and 90 min post-injection (p. i.). The collected blood samples were weighed and counted for radioactivity in a γ-counter. Anterior and posterior planar γ-camera images were collected at 10, 20, 30, 60, 90, and 120 min after injection, with organ uptake quantified by region-of-interest (ROIs) analysis. For comparison, 99Tcm-MIBI was also evaluated in the same twelve dogs. Canine infarct models were set up by micro-invasive interventional embolization. SPECT images in the canine infarct model were collected 24 hours after myocardial infarction at 30 min and 60 min after the administration of 99Tcm N-MPO (n = 5) or 99Tcm-MIBI (n = 5). Results Both of 99Tcm N-MPO and 99Tcm-M1BI had a rapid blood clearance with less than 50% of initial radioactivity remaining at 1 min [99TcmN-MPO: (35. 77 ± 6. 31)% ID/mg ,99Tcm-MIBI (34. 46 ± 6. 83) % ID/mg] and less than 5% at 30 min p. i. [99Tcm N-MPO(3. 11 ± 1.44) % ID/mg,99Tcm-MIBI (2.93 ±0. 39)% ID/mg] . After injection, 99TcmN-MPO showed significant accumulation in the myocardium and prolonged retention. This rapid liver clearance of 99TcmN-MPO led to favorable heart-to-liver ratios, reaching values of 0. 54 ±0. 06 at 10 min, 1.02 ±0. 06 at 30 min, and 1.38 ±0. 06 at 60 min p. i.In contrast, the heart/liver ratio of 99Tcm-MIBI remained low at all time points (0. 46 ± 0. 03 at 10 min,0. 63 ±0. 03 at 30 min, and 0. 62 ± 0. 12 at 60 min p. i.). SPECT imaging studies in canines with acute myocardial infarction indicated that good visualization of the left ventricular wall and perfusion defects could be achieved at 30 min after administration of 99TcmN-MPO, but not 99Tcm-MIBI. Conclusion The combination of high heart uptake and rapid liver clearance makes 99TcmN-MPO a promising new radiotracer for myocardial perfusion imaging.

关 键 词:心肌梗死   放射性同位素   体层摄影术,发射型计算机,单光子   

A comparative study of 99Tcm N-mercaptopyridine-N-oxide and 99Tcm-sestamibi myocardial perfusion imaging on acute myocardial infarction canine model
SHA Fei,WEN Xiao-fei,BU Li-hong,LI Ren-fei,ZHANG Tong,JIN Zhong-nan,SHEN Bao-zhong. A comparative study of 99Tcm N-mercaptopyridine-N-oxide and 99Tcm-sestamibi myocardial perfusion imaging on acute myocardial infarction canine model[J]. Chinese Journal of Radiology, 2010, 45(12): 392-398. DOI: 10.3760/cma.j.issn.1005-1201.2011.04.016
Authors:SHA Fei  WEN Xiao-fei  BU Li-hong  LI Ren-fei  ZHANG Tong  JIN Zhong-nan  SHEN Bao-zhong
Abstract:
Keywords:Myocardial infarctionRadioisotopesTomography  emission-computed  singlephoton
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号