旋转调强与固定野逆向调强放疗在颅脑多发转移瘤中的剂量学比较研究
引用本文:林秀桐,孙涛,王传栋,尹勇,刘同海,陈进琥. 旋转调强与固定野逆向调强放疗在颅脑多发转移瘤中的剂量学比较研究[J]. 中华放射医学与防护杂志, 2010, 30(4): 585-590. DOI: 10.3760/cma.j.issn.0254-5098.2010.05.024
作者姓名:林秀桐  孙涛  王传栋  尹勇  刘同海  陈进琥
作者单位:山东省肿瘤医院放疗科物理室,山东省放射肿瘤学重点实验室,济南,250117;山东潍坊安丘市人民医院放疗科;
摘    要:Objective To evaluate the performace of fixed field Intensity modulated radiation therapy (IMRT) and RapidArc in the radiotherapy for multiple intracranial metastases.Methods The clinical data of 10 patients with multiple intracranial metastases,8 male and 2 female,aged 65-73,were used to design 3 plans:fixed field IMRT,RapidArc with single Arc (RA1),and RapidArc with double Arc (Arc 2).Dose-volume-histogram analysis was used to compare dose results,monitor unit,and delivery time.Results All 3 plans met the clinical requirements.The best target conformity and homogeneity were observed in the RA2 plan (Z = -2.803,- 2.904,P < 0.05) and there were no statistical differences between the IMRT plan and RA1 plan.The maximum doses to the lens,eyes,and brainstem of the two RapidArc plans were all significantly lower than those of the IMRT plan(Z = -2.803--2.191 ,P <0.05),and the maximum dose to the optic nerves of the RA2 plan was significantly lower than that of the IMRT plan (Z = -2.293,-2.701 ,P <0.05).Compared with the IMRT plan,the average monitor units of the RA1 and RA2 plans were reduced by 29% and 24%,respectively,and the delivery time of these plans were significantly shorter by 84% and 69%,respectively.Conclusions Compared to the IMRT plan,RapidArc plans with single or double Arcs show similar or better effects in the target dose distribution,reduction of irradiation doses on organs at risk and,moreover,significant decrease of the monitor units and delivery time.

关 键 词:旋转调强   逆向调强放疗   多发颅脑转移   剂量学   

Dosimetric comparison of fixed field intensity modulated radiation therapy and RapidArc volumetric modulated arc therapy in treatment of multiple intracranial metastases
LIN Xiu-tong,SUN Tao,WANG Chuan-dong,YIN Yong,LIU Tong-hai,CHEN Jin-hu. Dosimetric comparison of fixed field intensity modulated radiation therapy and RapidArc volumetric modulated arc therapy in treatment of multiple intracranial metastases[J]. Chinese Journal of Radiological Medicine and Protection, 2010, 30(4): 585-590. DOI: 10.3760/cma.j.issn.0254-5098.2010.05.024
Authors:LIN Xiu-tong  SUN Tao  WANG Chuan-dong  YIN Yong  LIU Tong-hai  CHEN Jin-hu
Abstract:
Keywords:Intensity-modulated Arc radiotherapyIntensity modulated radiotherapyMultiple intracranial metastasesDosimetry