首页 | 本学科首页   官方微博 | 高级检索  
     

���޲����������Ѫ��ϸ����ֲ���ߵİ�����ѪҩŨ��
引用本文:л����,��ѩ÷,ׯ����,����,����,ԪС��,������,�ν�,¥����. ���޲����������Ѫ��ϸ����ֲ���ߵİ�����ѪҩŨ��[J]. 中国药学杂志, 2015, 50(16): 1424-1429. DOI: 10.11669/cpj.2015.16.014
作者姓名:л����  ��ѩ÷  ׯ����  ����  ����  ԪС��  ������  �ν�  ¥����
作者单位:1. ?????????????Э????, a.????; b.????, ???? 350001;
2.??????????????????о??,???? 350001
摘    要:

关 键 词:??????  ????  ?????????  ???????  

Limited Sampling Strategies for Clinical Plasma Concentration Monitoring of Busulfan in Hematopoietic Stem Cell Transplantation Patients
XIE He-lin,WU Xue-mei,ZHUANG Bo-yang,YANG Ting,HUANG Xian,YUAN Xiao-hong,LI Xiao-fan,REN Jin-hua,LOU Yong-ming. Limited Sampling Strategies for Clinical Plasma Concentration Monitoring of Busulfan in Hematopoietic Stem Cell Transplantation Patients[J]. Chinese Pharmaceutical Journal, 2015, 50(16): 1424-1429. DOI: 10.11669/cpj.2015.16.014
Authors:XIE He-lin  WU Xue-mei  ZHUANG Bo-yang  YANG Ting  HUANG Xian  YUAN Xiao-hong  LI Xiao-fan  REN Jin-hua  LOU Yong-ming
Affiliation:1a.Department of Pharmacy, b.Department of Hematology Fujian Medical University Union Hospital, Fuzhou 350001, China;
2.Fujian Institute for Food and Drug Outity Control, Fuzhou 350001, China
Abstract:??OBJECTIVE To establish limited sampling strategy to estimate area under the curve (AUC) of HSCT patients who had received busulfan (Bu) intravenous infusion. METHODS Plasma samples were collected at certain time points from 22 HSCT patients who had received busulfan intravenous infusion. The LC-MS/MS method was used to measure blood concentration of busulfan. The classical method was used to calculate pharmacokinetic parameters. To estimate AUC0-6, measured blood concentration data was used to build a multiple linear regression model which was subsequently validated. Consistency between results produced by the traditional method and the proposed LSS respectively was assessed by the intraclass correlation coefficient (ICC) and Bland-Altman (BA) analysis. RESULTS It is shown that model based on concentrations on two sampling time points (2 and 5 h) is able to predict AUC0-6accurately (adjusted r2=0.917. MPE=0.2%, RMSE=4.48%). The 95% confidence interval of ICC is 0.914-0.984 while the limit of agreement in the BA is -0.9-8.8. Results produced by limited sampling strategy are nearly consistent with AUC0-6 produced by the classical method. CONCLUSION The proposed limited sampling strategy to estimate AUC0-6 based on C2 and C5 can be used to busulfan blood concentration monitoring in clinical practice.
Keywords:
点击此处可从《中国药学杂志》浏览原始摘要信息
点击此处可从《中国药学杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号