首页 | 本学科首页   官方微博 | 高级检索  
     

��������ӡ���붨��������ҩ��ѧ�о��е�Ӱ������
引用本文:������,�̾���,�����,����һ,���,���ľ�,���ڸ�. ��������ӡ���붨��������ҩ��ѧ�о��е�Ӱ������[J]. 中国药学杂志, 2015, 50(9): 758-762. DOI: 10.11669/cpj.2015.09.006
作者姓名:������  �̾���  �����  ����һ  ���  ���ľ�  ���ڸ�
作者单位:1.?й???????????Э??????????\???о???,???? 100050;
2.?й???????????Э?????????о???, ???? 100050
摘    要:


关 键 词:???????????  ????  ???????  ???????  

Impact Factors on Results of Semi-Quantitative Western Blot in Pharmacological Research
JIANG Chen-chen,CHENG Jun-jun,HUANG Meng-hao,WU Zhou-yi,LI Jian-rui,LI Wen-jing,PENG Zong-gen. Impact Factors on Results of Semi-Quantitative Western Blot in Pharmacological Research[J]. Chinese Pharmaceutical Journal, 2015, 50(9): 758-762. DOI: 10.11669/cpj.2015.09.006
Authors:JIANG Chen-chen  CHENG Jun-jun  HUANG Meng-hao  WU Zhou-yi  LI Jian-rui  LI Wen-jing  PENG Zong-gen
Affiliation:1. Institute of Medicinal Biotechnology, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100050, China;
2. Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100050, China
Abstract:
??OBJECTIVE To investigate the impact factors of the semi-quantitative Western blot (WB), offering a guidance on research of pharmacological effects of drugs at the level of proteins. METHODS Total proteins were extracted from the Huh7.5 cells infected with hepatitis C virus and quantified with BCA kit, HCV Core protein was chose as target protein, and protein Tubulin or Gapdh, which was encoded by housekeeping gene, as the internal control. By controlling the experimental factors, such as loading sample amount, concentration and the incubation time of first antibodies, and dilutions of chemiluminescent fluid as well, we analyzed those factors how to impact the semi-quantitative results. RESULTS The semi-quantitative results showed that there is a linear relationship between relative intensity of target protein and the amount of total protein at must protein concentration range, beyond which, the rangeability of relative intensity of target protein reduced, even no changes. However, sample volume loaded, or protein selected as internal reference has little influence on the result of semi-quantitative WB. In the context of obtaining high-quality band, concentration and incubation time of antibodies or dilution of chemiluminescent fluid also has no influence on it. Yet, the semi-quantitative WB has certain defects and our results show that the permissible error of semi-quantitative result should be controlled within 15%. CONCLUSION The key impact factor on the result of semi-quantitative WB is the target protein amount of loading. On the premise of obtaining clear and high-quality bands, appropriately selecting loading volume of samples, concentration and incubation time of first antibodies, and dilutions of chemiluminescent fluid is conducive to accomplish experiments without affecting the final results of semi-quantitative WB.
Keywords:
点击此处可从《中国药学杂志》浏览原始摘要信息
点击此处可从《中国药学杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号