Thickening of the inferior glenohumeral capsule: an ultrasound sign for shoulder capsular contracture
Authors:Paul Michelin  Yohann Delarue  Fabrice Duparc  Jean Nicolas Dacher
Affiliation:1. Department of Radiology, University Hospital of Rouen, 1, Rue de Germont, 76031, Rouen Cedex, France
2. Regional Center for Physical Medicine and Rehabilitation, Bois-Guillaume, France
3. Department of Orthopedic Surgery and Traumatology, University Hospital of Rouen, Rouen, France
Abstract:

Objectives

The aim of this retrospective study was to measure the inferior glenohumeral capsule thickness of shoulders clinically affected by capsular contracture by comparison to the contralateral asymptomatic side.

Methods

Bilateral shoulder ultrasound (US) examinations of 20 patients with clinically or MRI proven unilateral capsular contracture were retrospectively assessed. Inferior capsule evaluation was performed with a transducer placed within the axilla in maximally abducted shoulders. Measurements were symmetrically performed orthogonally to the inferior glenohumeral ligament (IGHL) in the axial plane; the coronal plane was used to ensure the tension of the IGHL. The significance of any difference in thickening was assessed with the Mann–Whitney test.

Results

The average thickness was 4.0 mm in shoulders with capsular contracture vs. 1.3 mm in asymptomatic contralateral shoulders (P?Conclusion The thickness of the inferior capsule is measurable through ultrasound examination and appears to be increased in shoulders with capsular contracture. Exploration of the inferior aspect of the shoulder joint could be added to shoulder US examination protocols for capsular contracture assessment even if other rotator cuff abnormalities are diagnosed by US.

Key Points

? Ultrasound is increasingly used to diagnose shoulder problems. ? The thickness of the inferior glenohumeral ligament is measurable in the axilla. ? The inferior glenohumeral ligament appears thickened in shoulders with capsular contracture. ? Capsular contracture ultrasound features can be associated with other rotator cuff problems.
Keywords: