首页 | 本学科首页   官方微博 | 高级检索  
     


Risk factors for intrauterine device failure: a review
Authors:Thonneau P  Goulard H  Goyaux N
Affiliation:Human Fertility Research Group, La Grave Hospital, Toulouse, France. thonneau.p@chu-toulouse.fr
Abstract:After reviewing the literature on intrauterine devices (IUDs) published over the last 30 years, we selected and analyzed recent and most relevant (with appropriate methodology design) articles dealing with the risk factors for IUD failure. There is sufficient evidence to conclude that the TCu380 and levonorgestrel-releasing (LNG) IUD are the most effective, with a cumulative pregnancy rate of less than 2% at 12 years for the TCu380 and around 1% for the LNG IUD at 7 years. In addition, advancing age increases IUD effectiveness, and displacement of the IUD decreases effectiveness. The IUDs with the highest copper concentrations are clearly less prone to failure than those with lower copper concentrations.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号