首页 | 本学科首页   官方微博 | 高级检索  
     

单向高激励次数序列对肝脏DWI图像质量及表观弥散系数的影响
引用本文:胥津歌,孙楠,史燕杰,闫铄,李晓婷,孙应实. 单向高激励次数序列对肝脏DWI图像质量及表观弥散系数的影响[J]. 中国医学影像技术, 2021, 37(4): 552-556
作者姓名:胥津歌  孙楠  史燕杰  闫铄  李晓婷  孙应实
作者单位:北京大学肿瘤医院暨北京市肿瘤防治研究所医学影像科 恶性肿瘤发病机制及转化研究教育部重点实验室, 北京 100142
基金项目:国家重点研发计划(2019YFC0117705)、北京市自然科学基金(Z20J0015)、北京市医院管理中心"登峰"计划专项(DFL20191103)、北京市医院管理局"扬帆"计划重点医学专业发展计划(ZYLX201803)。
摘    要:目的 观察单向高激励次数(NEX)序列对肝脏DWI图像质量及表观弥散系数(ADC)的影响.方法 对21例肝脏疾病患者(疾病组)和26名志愿者(健康组)采集单向高NEX序列及常规序列DWI图像,对比不同序列DWI及ADC图像质量主观评分,包括显示病灶、解剖结构和伪影情况;测量肝左、右叶肝实质及病灶的信噪比(SNR)及AD...

关 键 词:  弥散加权成像  激励次数  信噪比
收稿时间:2021-01-11
修稿时间:2021-03-23

Impact of single-direction high number of excitation sequence on imaging quality of diffusion weighted imaging of liver
XU Jinge,SUN Nan,SHI Yanjie,YAN Shuo,LI Xiaoting,SUN Yingshi. Impact of single-direction high number of excitation sequence on imaging quality of diffusion weighted imaging of liver[J]. Chinese Journal of Medical Imaging Technology, 2021, 37(4): 552-556
Authors:XU Jinge  SUN Nan  SHI Yanjie  YAN Shuo  LI Xiaoting  SUN Yingshi
Affiliation:Department of Medical Imaging, Peking University Cancer Hospital&Institute, Key Laboratory of Carcinogenesis and Translational Research, Beijing 100142, China
Abstract:Objective To explore the impact of single-direction high number of excitation (NEX) squence on image quality of liver diffusion weighted imaging (DWI) and apparent diffusion coefficient (ADC). Methods A total of 21 patients with liver diseases (disease group) and 26 volunteers (healthy group) were enrolled. Single-direction high NEX sequence and conventional sequence DWI images were collected, and subjective scores of DWI and ADC image quality under different sequences, including lesion display, anatomical structure and artifacts were compared. The signal to noise ratio (SNR) and ADC of liver parenchyma and lesions of left and right hepatic lobes were measured, and coefficient of variation (CV) were calculated. Results The artifacts scores of left hepatic lobe with single-direction high NEX sequence were higher than conventional sequences on DWI and ADC images, and SNR of single-direction high NEX sequence of liver parenchyma of the left lobe were higher than those of the conventional sequence in both 2 groups (all P<0.05). ADC of liver parenchyma and/or the lesions of the left and right hepatic lobes in 2 groups were not statistically different between single-direction high NEX sequence and conventional sequences (all P>0.05), and CV of single-direction high NEX sequence were all lower than that of conventional sequences (all P<0.05). Conclusion Single-direction high NEX sequences could improve DWI image quality of left hepatic lobe without affecting ADC.
Keywords:liver  diffusion weighted imaging  number of excitation  signal-to-noise ratio
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏