首页 | 本学科首页   官方微博 | 高级检索  
检索        


Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imaging
Authors:Fütterer Jurgen J  Heijmink Stijn W T P J  Scheenen Tom W J  Veltman Jeroen  Huisman Henkjan J  Vos Pieter  Hulsbergen-Van de Kaa Christina A  Witjes J Alfred  Krabbe Paul F M  Heerschap Arend  Barentsz Jelle O
Institution:Department of Radiology, Radboud University Nijmegen Medical Center, Geert Grooteplein zuid 10, NL 6500 HB, Nijmegen, the Netherlands. J.Futterer@rad.umcn.nl
Abstract:PURPOSE: To prospectively determine the accuracies of T2-weighted magnetic resonance (MR) imaging, dynamic contrast material-enhanced MR imaging, and quantitative three-dimensional (3D) proton MR spectroscopic imaging of the entire prostate for prostate cancer localization, with whole-mount histopathologic section findings as the reference standard. MATERIALS AND METHODS: This study was approved by the institutional review board, and informed consent was obtained from all patients. Thirty-four consecutive men with a mean age of 60 years and a mean prostate-specific antigen level of 8 ng/mL were examined. The median biopsy Gleason score was 6. T2-weighted MR imaging, dynamic contrast-enhanced MR imaging, and 3D MR spectroscopic imaging were performed, and on the basis of the image data, two readers with different levels of experience recorded the location of the suspicious peripheral zone and central gland tumor nodules on each of 14 standardized regions of interest (ROIs) in the prostate. The degree of diagnostic confidence for each ROI was recorded on a five-point scale. Localization accuracy and ROI-based receiver operating characteristic (ROC) curves were calculated. RESULTS: For both readers, areas under the ROC curve for T2-weighted MR, dynamic contrast-enhanced MR, and 3D MR spectroscopic imaging were 0.68, 0.91, and 0.80, respectively. Reader accuracy in tumor localization with dynamic contrast-enhanced imaging was significantly better than that with quantitative spectroscopic imaging (P < .01). Reader accuracy in tumor localization with both dynamic contrast-enhanced imaging and spectroscopic imaging was significantly better than that with T2-weighted imaging (P < .01). CONCLUSION: Compared with use of T2-weighted MR imaging, use of dynamic contrast-enhanced MR imaging and 3D MR spectroscopic imaging facilitated significantly improved accuracy in prostate cancer localization.
Keywords:
本文献已被 PubMed 等数据库收录!
点击此处可从《Radiology》浏览原始摘要信息
点击此处可从《Radiology》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号