HIFU消融治疗中监控定位的B超伪像
引用本文:王勇刚,林涛,吴丹丹,王琦,钟珊珊. HIFU消融治疗中监控定位的B超伪像[J]. 中国医学影像技术, 2010, 26(6): 1165-1168
作者姓名:王勇刚  林涛  吴丹丹  王琦  钟珊珊
作者单位:1. 重庆医科大学生物医学工程系,超声医学工程重庆市市级重点实验室,重庆市超声医学工程重点实验室-省部共建国家重点实验室培育基地,重庆,400016
2. 超声医疗国家工程研究中心,重庆,401120
基金项目:国家自然科学基金重点项目,国家自然科学基金面上项目 
摘    要:目的 探讨HIFU消融治疗中B超伪像到探头、探头到目标组织以及治疗头到目标组织三者之间的距离关系. 方法 在不同位置固定治疗头到目标组织的距离,分别测量伪像到探头以及目标组织到探头之间的距离. 结果伪像到探头的距离和目标组织到探头的距离之间呈线性变化关系. 结论 本实验中伪像的形成主要由B超探头引起,与治疗头的位置基本无关.

关 键 词:伪像  超声学  距离  高强度聚焦超声消融
收稿时间:2010-01-28
修稿时间:2010-03-19

Artifact of type-B ultrasound in monitoring and allocation of HIFU ablation therapy
WANG Yong-gang,LIN Tao,WU Dan-dan,WANG Qi and ZHONG Shan-shan. Artifact of type-B ultrasound in monitoring and allocation of HIFU ablation therapy[J]. Chinese Journal of Medical Imaging Technology, 2010, 26(6): 1165-1168
Authors:WANG Yong-gang  LIN Tao  WU Dan-dan  WANG Qi  ZHONG Shan-shan
Affiliation:Department of Biomedical Engineering in Chongqing Medical University, Chongqing Key Laboratory of Ultrasound Medical Engineering, Sate Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and MOST, Chongqing 400016, China;National Engineering Research Center for Ultrasound Medicine, Chongqing 401120, China;National Engineering Research Center for Ultrasound Medicine, Chongqing 401120, China;National Engineering Research Center for Ultrasound Medicine, Chongqing 401120, China;Department of Biomedical Engineering in Chongqing Medical University, Chongqing Key Laboratory of Ultrasound Medical Engineering, Sate Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and MOST, Chongqing 400016, China
Abstract:Objective To assess the distance relationships among the artifacts of type-B ultrasound and the probe, the probe and the target tissue, as well as the transducer and the target tissue. Methods The distance between the transducer and the target tissue in different locations was located, and the distance between the artifact and the probe, as well as the target tissue and the probe was measured respectively. Results The distance between the artifact and the probe changed linearly when the distance changed between the target tissue and the probe. Conclusion In this experiment, artifacts are mainly caused by ultrasound probe, not correlated much with the position of the transducer.
Keywords:Artifact  Ultrasonics  Distance  High-intensity focused ultrasound ablation