首页 | 本学科首页   官方微博 | 高级检索  
     

高频部分液体通气对吸入性损伤犬血液动力学影响的实践研究
引用本文:钱克俭,郭光华,王联群,熊龙,赵为禄,李国辉,曹勇. 高频部分液体通气对吸入性损伤犬血液动力学影响的实践研究[J]. 中国急救医学, 2002, 22(2): 65-66
作者姓名:钱克俭  郭光华  王联群  熊龙  赵为禄  李国辉  曹勇
作者单位:1. 江西医学院第一附属医院ICU,330006
2. 江西医学院第一附属医院烧伤科,330006
基金项目:国家自然科学基金资助项目 (No 3 9760 0 73 ),江西省主要学科跨世纪学术和技术带头人培养计划基金资助项目 (No .K990 5 0 2 )
摘    要:目的 观察高频喷射通气结合小剂量氟碳 (3mL/kg)液体通气对吸入性损伤犬的血流动力学影响。方法 将16条犬经蒸气吸入造成吸入性损伤模型 ,并随机分为两组 ,即对照组和治疗组。两组动物致伤后均行高频喷射通气 ,但治疗组动物同时经气管导管将氟碳液体 (3mL/kg)缓慢注入肺内 ,在 90min内测定血流动力学指标。结果 治疗组动物的心率(HR)、平均动脉压 (PAP)、肺动脉嵌压 (PAWP)、心输出量 (CO)及每搏量 (SV)与伤后比较无统计意义 (P >0 0 5 ) ,但PAP在通气治疗 6 0、90min后与伤后比较略有升高 (P <0 0 5 ) ,HR、MAP、PAP、PAWP、CO及SV与对照组比较无统计意义 (P >0 0 5 )。结论 高频喷射通气合并小剂量氟碳 (3mL/kg)部分液体通气对吸入性损伤犬的血流动力学的主要参数无不利影响。

关 键 词:高频喷射通气 部分液体通气 吸入性损伤 血流动力学 机械通气 动物实验
文章编号:1002-1949(2002)02-0065-02
修稿时间:2001-10-15

Experimental study of high frequency jet ventilation combined with perfluorcarbon partial liquid ventilation on the hemodynamic influence of the inhalation injuried dogs
QIAN Ke-jian ,GUO Guang-hua ,WANG Lian-qun ,et al.. Experimental study of high frequency jet ventilation combined with perfluorcarbon partial liquid ventilation on the hemodynamic influence of the inhalation injuried dogs[J]. Chinese Journal of Critical Care Medicine, 2002, 22(2): 65-66
Authors:QIAN Ke-jian   GUO Guang-hua   WANG Lian-qun   et al.
Affiliation:QIAN Ke-jian 1,GUO Guang-hua 2,WANG Lian-qun 1,et al. 1 Department of Anesthesiology,First Affiliated Hospital,Jiangxi Medical College,Nanchang 330006,China
Abstract:Objective To study high frequency jet ventilation combined with perfluorcarbon partial liquid ventilation on hemodynamic effect of inhalation injury. Methods 16 dogs with inhalation injury from steam were divided into control group and treatment group at random. Both groups were given high frequency jet ventilation after injury, and treatment group were simulataneously injected with perfluorocarbon liquid(3 mL/kg) into lungs slowly. Hemodynamics were examined at different time sited within 90 minutes. Results There is no statistical significance in hemodynamics between two group. Conclusion High frequency jet ventilation combined with low volume perfluorocarbon(3 mL/kg) liquid ventilation do not has adverse hemodynamic effect.
Keywords:Perfluorocarbon  HFJV  Partial liquid ventilation  Inhalation injury  Dog  Hemodynamics
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏