首页 | 本学科首页   官方微博 | 高级检索  
     

GlideScope视频喉镜与光导纤维支气管镜经口气管插管对血流动力学影响的比较
引用本文:Zhang GH,Xue FS,Li CW,Sun HY,Li XY,Sun HT,Liu KP. GlideScope视频喉镜与光导纤维支气管镜经口气管插管对血流动力学影响的比较[J]. 中国医学科学院学报, 2006, 28(3): 406-409
作者姓名:Zhang GH  Xue FS  Li CW  Sun HY  Li XY  Sun HT  Liu KP
作者单位:中国医学科学院,中国协和医科大学,整形外科医院麻醉科,北京,100041
摘    要:目的比较全身麻醉诱导后采用GlideScope视频喉镜(GSVL)和光导纤维支气管镜(FOB)经口气管插管对血流动力学的影响。方法施择期整形外科手术患者57例,随机分为GSVL组(n=29)和FOB组(n=28)。在常规静脉麻醉诱导后实施气管插管操作。监测麻醉诱导前、后,气管插管时和气管插管后1、2、3、4、5min的血压和心率变化。结果GSVL组与FOB组气管插管时间差异无显著性(P>0·05)。气管插管后两组患者的血压和心率均比麻醉诱导后明显升高,但血压最大值未超过麻醉诱导前水平,而心率最大值较麻醉诱导前显著升高。两组在观察期各对应时间点的血压和心率及血压和心率最大值差异均无显著性(P>0·05)。结论GSVL经口气管插管可引起与FOB经口气管插管相同程度的心血管系统应激反应。

关 键 词:GlideScope视频喉镜  光导纤维支气管镜  全身麻醉  经口气管插管  血流动力学
文章编号:1000-503X(2006)03-0406-04
收稿时间:2005-07-09
修稿时间:2005-07-09

Comparison of hemodynamic responses to orotracheal intubation between using GlideScope videolaryngoscope and fiberoptic bronchoscope
Zhang Guo-Hua,Xue Fu-Shan,Li Cheng-Wen,Sun Hai-Yan,Li Xuan-Ying,Sun Hai-Tao,Liu Kun-Peng. Comparison of hemodynamic responses to orotracheal intubation between using GlideScope videolaryngoscope and fiberoptic bronchoscope[J]. Acta Academiae Medicinae Sinicae, 2006, 28(3): 406-409
Authors:Zhang Guo-Hua  Xue Fu-Shan  Li Cheng-Wen  Sun Hai-Yan  Li Xuan-Ying  Sun Hai-Tao  Liu Kun-Peng
Affiliation:Department of Anesthesiology, Plastic Surgery Hospital, CAMS and PUMC, Beijing 100041, China
Abstract:OBJECTIVE: To compare the hemodynamic responses to orotracheal intubation with GlideScope videolaryngoscope (GSVL) and with fiberoptic bronchoscope (FOB) after induction of general anesthesia. METHODS: Totally 57 ASA physical status I - II adult patients undergoing elective plastic surgery and requiring orotracheal intubation were randomly allocated to either GSVL group (n = 29) or FOB group (n = 28). After a routine intravenous anesthetic induction, orotracheal intubation was performed. Noninvasive blood pressure (BP) and heart rate (HR) were recorded before and after anesthetic induction, at intubation and thereafter at 1 minute interval for 5 minutes. RESULTS: The intubation time was not significantly different between the two groups (P > 0.05). After intubation, BP and HR exhibited significant increases compared to the post-induction values in both groups, but the maximum values of BP did not exceed the pre-induction values while the maximum value of HR was higher than the pre-induction value. During the observation, BP and HR at all time points as well as the maximum values of BP and HR had no significant differences between the two groups (P > 0.05). CONCLUSION: The orotracheal intubations using FOB and GSVL result in similar hemodynamic responses.
Keywords:GlideScope videolaryngoscope  fiberoptic bronchoscope  general anesthesia  intubation  hemodynamic  
本文献已被 CNKI 维普 万方数据 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号