两种颌托在颊侧多曲簧作用下对牙齿作用力的对比实验
引用本文:陈萍,王培军,石瑛琦,徐实谦,侯录. 两种颌托在颊侧多曲簧作用下对牙齿作用力的对比实验[J]. 口腔医学, 2021, 41(1): 38-42. DOI: 10.13591/j.cnki.kqyx.2021.01.008
作者姓名:陈萍  王培军  石瑛琦  徐实谦  侯录
作者单位:1. 哈尔滨医科大学附属第二医院2. 哈尔滨医科大学附属第二临床医院3. 哈尔滨工业大学
摘    要:目的 比较自凝树脂材料和热压膜材料制作的颌托,在颊侧多曲簧矫治力的作用下对上下颌中切牙的力值,以期选用合适材料代替自凝树脂制作颌托,为解决在临床应用颊侧多曲簧矫治器矫治安氏Ⅲ类错(牙合)畸形过程中,部分患者前牙出现的唇舌向倾斜问题提供参考.方法 口外模拟闭口位状态,将颊侧多曲弹簧依次矢状向打开2 mm、4 mm、6 m...

关 键 词:颊侧多曲簧矫治器  自凝树脂  热压膜  薄膜压力传感器
收稿时间:2020-02-06

The force of two different kinds of denture bases on teeth under the function of the buccal multiloop appliance
CHEN Ping,WANG Peijun,SHI Yingqi,XU Shiqian,HOU Lu. The force of two different kinds of denture bases on teeth under the function of the buccal multiloop appliance[J]. Stomatology, 2021, 41(1): 38-42. DOI: 10.13591/j.cnki.kqyx.2021.01.008
Authors:CHEN Ping  WANG Peijun  SHI Yingqi  XU Shiqian  HOU Lu
Affiliation:(Department of Orthodontics,the Second Affiliated Hospital of Harbin Medical University,,Harbin 150000.China)
Abstract:Objective To compare the forces on the upper and lower central incisors of bases made of different materials,self-curing resin materials and the thermoplastic materials,under the action of buccal multiple spring,hoping to choose proper materials to replace the bases made of self-curing resin and to solve the problem of anterior teeth inclination in patients treated with buccal multiloop appliance during the process of correcting ClassⅢmalocclusion.Methods According to voltage-force value relation,the voltage value could be converted into force value.The voltage on the incisors was measured by a thin film pressure sensor miniature force system when the buccal multiloop was opened for 2 mm,4 mm,6 mm,8 mm,10 mm respectively in the simulated closed position in vitro.Force values on the labial and lingual surfaces of the upper central incisors under the orthodontic force of different lengths of buccal multiloop springs were calculated and compared.Then the results were statistically analyzed.Results With the increase of the length of buccal multiloop,the force values produced by the two kinds of bases on the labial surface of maxillary central incisors and the lingual surface of mandibular central incisors increased.When the buccal multiloop was opened to the same length,the labial force values of the thermoplastic material base on maxillary central incisors and the lingual force values of mandibular central incisors of that were less than those of the self-curing resin base(P<0.05).Conclusion Compared with self-curing resin,the force value of the base made of the thermoplastic material on maxillary and mandibular central incisors is smaller,which can reduce the inclination of maxillary and mandibular central incisors and relieve the tooth effect.
Keywords:buccal multiloop appliance  self-curing resin  thermoplastic material  thin film pressure sensor