重组人心肌肌钙蛋白I纯化方法的对比 |
| |
引用本文: | 郝庆钦,周建平,许秀丽,刘培,温新宇,王玲,田亚平. 重组人心肌肌钙蛋白I纯化方法的对比[J]. 国际检验医学杂志, 2014, 0(14): 7-8,1820 |
| |
作者姓名: | 郝庆钦 周建平 许秀丽 刘培 温新宇 王玲 田亚平 |
| |
作者单位: | 郝庆钦(中国人民解放军总医院生化科,北京 100853 南开大学医学院,天津 300071); 周建平 (军事医学科学院毒物药物研究所,北京,100850); 许秀丽(中国人民解放军总医院生化科,北京 100853 南开大学医学院,天津 300071);刘培(中国人民解放军总医院生化科,北京 100853 南开大学医学院,天津 300071); 温新宇 (中国人民解放军总医院生化科,北京,100853); 王玲 (中国人民解放军总医院生化科,北京,100853); 田亚平 (中国人民解放军总医院生化科,北京,100853); |
| |
基金项目: | 国家高技术研究发展计划(863计划)资助项目(2011AA02A111). |
| |
摘 要: | 目的:对比两种重组人心肌肌钙蛋白 I(rhcTnI)纯化方法,获取稳定的 rhcTnI,促进心肌肌钙蛋白(cTnI)诊断标准化的研究。方法超声破碎工程菌获取 rhcTnI 包涵体,经2% Tritonx-100,2 mol/L 脲洗涤后溶解在8 mol/L 脲中,分别经 CM-FF 柱上复性和稀释复性纯化 rhcTnI,对比两种方法纯化 rhcTnI 的获得率及其产物在4、-20、-80℃及冻干条件下的稳定性,确立高效获取稳定的 cTnI 的纯化方法。结果0.1 g 湿重包涵体经 CM-FF 柱上复性和稀释复性的获得率分别为26.8%和18.9%。4、-20、-80℃及冻干条件下,CM-FF 下柱上复性获得的 rhcTnI 稳定,并且柱上复性纯化周期短,效率高。结论 CM-FF 柱上复性要比稀释复性纯化 rhcTnI 高效、稳定。
|
关 键 词: | 心肌肌钙蛋白I 稀释复性 柱上复性 纯化 |
Comparison in purification methods of the recombinant human cardiac troponin I |
| |
Affiliation: | Hao Qingqin, Zhou Jianping, Xu Xiuli, Liu Pei, Wen Xinyu, Wang Ling, Tian Yaping ( 1. Department of Clinical Biochemistry, General Hospital of PLA, Beijing 100853, China ; 2. School of Medicine , Nankai University, Tianj in 300071 ,China;3. Research Institute of Pharmacology and Toxicology,Military Medical Science Academy of PLA ,Beijing 100850 ,China) |
| |
Abstract: | Objective To compare the two kinds of purification method for purifying recombinant human cardiac troponin I(cT-nI)to obtain the stable cTnI and promote the study of cTnI diagnosis standardization.Methods The cTnI inclusion body was ob-tained by the ultrasonic broken engineering,after washing by 2% Tritonx-100,2M urea,dissolved in 8M urea,then purified by the column refolding on CM-FF and the dilution refolding respectively.The cTnI yields were compared between the two kinds of meth-od and the stability at 4 ℃,20 ℃,-80 ℃ and on the freeze-dried condition was compared.Then the purification method to effi-ciently obtain the stable cTnI was established.Results The protein about 2 mg and 1.4 mg could be obtained by CM-FF on the col-umn refolding and the dilution refolding from 0.1 g of wet inclusion body,respectively.The former method had the short cycle and high efficiency.The cTnI purified by the column refolding on CM-FF was more stable at 4 ℃,20 ℃,-80 ℃ and on the freeze-dried condition.Conclusion The column refolding on CM-FF is more stable and highly efficient in purification of cTnI than the dilution refolding. |
| |
Keywords: | cardiac troponin I dilution refolding column refolding purification |