首页 | 本学科首页   官方微博 | 高级检索  
检索        


Multi slice computed tomography in the study of pulmonary metastases
Authors:G Angelelli  V Grimaldi  F Spinelli  A Scardapane  A Sardaro
Institution:DiMIMP, Sezione di Diagnostica per Immagini, Università degli Studi di Bari, Piazza Giulio Cesare 11, 70124 Bari, Italy. g.angelelli@radiologia.uniba.it
Abstract:

Purpose

This study was undertaken to assess the performance of 16-slice computed tomography (MSCT) using Multi-Planar Reformatting (MPR), Maximum Intensity Projection (MIP) and Volume Rendering (VR) reconstructions to study pulmonary metastases.

Materials and methods

CT studies of 32 patients with pulmonary metastases were retrospectively reviewed. Images were assessed for the following parameters: number, size, location, distribution of the nodules and the presence of the “mass-vessel sign”. These parameters were evaluated by two observers on axial-source images and on MPR, MIP and VR reconstructions. Sensitivity of each reconstruction and interobserver agreement were calculated.

Results

Two-dimensional (2D) axial images and MIP and VR reconstructions exhibited 100% sensitivity for lesions >10 mm. For nodules 6–10 mm, sensitivity was 49%–55% for the 2D images, 90% for MIP and 80%–85% for VR reconstructions. For metastasis ≤5 mm, sensitivity was 22% for 2D images, 87%–89% for MIP and 55%–58% for VR reconstructions. Coronal and sagittal MPR, MIP and VR did not improve the detection rate compared with the corresponding axial images. MIP and VR provided overlapping results in detecting the “mass-vessel sign”.

Conclusions

MIP are the most sensitive reconstructions for detecting small pulmonary nodules.
Keywords:
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号