首页 | 本学科首页   官方微博 | 高级检索  
检索        


Reproducibility of placental maturity grade classification using a dynamic ultrasonography
Authors:Ricardo Ditzel Delle Donne  Edward Araujo Júnior  Liliam Cristine Rolo
Institution:1. Department of Obstetrics and Gynecology, Federal University of Paraná (UFPR), Curitiba, PR, Brazil and;2. Department of Obstetrics, Paulista School of Medicine, Federal University of S?o Paulo (EPM-UNIFESP), S?o Paulo, SP, Brazil
Abstract:Objective: To evaluate the agreement between ultrasonographers in classifying placental maturity grade using examination videos.

Methods: A prospective, cross-sectional study was conducted using 25 videos of ultrasonographic examinations of single, healthy pregnancies ≥?34?+?0 weeks. The Grannum (grades 0, I, II and III) and Julio (grades 0, 1, 2A, 2B and 3) classifications were used for placental maturity grade. The videos were evaluated on two occasions by 10 experienced ultrasonographers. Intra- and inter-observer agreements were evaluated using the Kappa (k) coefficient of agreement.

Results: According to the Grannum classification, the inter-observer agreement coefficients were good for grades III and 0 (k?=?0.69 and 0.738, respectively) and moderate for grades I and II (k?=?0.401 and 0.593, respectively) placentas. According to the Julio classification, the inter-observer agreement coefficients were good for grades 0 and 3 (k?=?0.738 and 0.651, respectively), moderate for grades 1 and 2A (0.401 and 0.413, respectively) and poor for grade 2B (k?=?0.161). Intra-observer coefficients for the Grannum and Julio classifications ranged from 0.567 to 0.890 and from 0.446 to 0.790, respectively.

Conclusion: Placental maturity grading using the Grannum and Julio classifications demonstrated moderate/good intra- and inter-observer agreements on examination videos evaluation.
Keywords:Grannum classification  placenta  reproducibility of results  ultrasonography