应用岛津D-visionplus-50行定点多轴位电视下摄影在肋骨隐匿性骨折中的诊断价值
引用本文:侯文光,张洁林,谢璇,江少国,李宋浩,陈思平. 应用岛津D-visionplus-50行定点多轴位电视下摄影在肋骨隐匿性骨折中的诊断价值[J]. 国际医药卫生导报, 2012, 18(22): 3295-3297
作者姓名:侯文光  张洁林  谢璇  江少国  李宋浩  陈思平
作者单位:515500,广东省揭东县人民医院
摘    要:目的比较岛津D—visionplus-50(多功能数字化透视摄影系统)痛点定点行多轴位电视下摄影和普通胸部照片在肋骨隐匿性骨折诊断价值。方法随机选择诊断明确的肋骨骨折患者120例,病例分三组;A组为随机抽取本院胶片存档式病例40例;B组为基层医院诊断不明确上送病例40例;C组为应用岛津D—visionplus-50多轴位痛点定位法电视下摄影患者40例。结果应用岛津D—visionplis-50痈点标记多轴位电视下摄影诊断肋骨骨折准确率高达97.33%,明显优于A组81.25%,更优于B组的67.69%。结论采用多功能数字化透视摄影系统结合定点多轴位电视下摄影临床诊断准确率明显高于其余两组,在诊断肋骨隐匿性骨折上有无可比拟的优越性。

关 键 词:定点摄影  多轴位  肋骨隐匿性骨折  可透视DR

Diagnosis value of Shimadzu D-vision plus-50 multi-axis TV photography in treatment for frame occult fracture
HOU Wen-guang , ZHANG Jie-lin , XIE Xuan , JIANG Shao-guo , LI Song-hao , CHEN Si-ping. Diagnosis value of Shimadzu D-vision plus-50 multi-axis TV photography in treatment for frame occult fracture[J]. International Medicine & Health Guidance News, 2012, 18(22): 3295-3297
Authors:HOU Wen-guang    ZHANG Jie-lin    XIE Xuan    JIANG Shao-guo    LI Song-hao    CHEN Si-ping
Affiliation:.(The People 's Hospital of Jiedong, Jiedong 515500, China)
Abstract:Objective To compare the diagnostic value of Shimadzu D-vislon plus-50 (multi- function digital perspective photography system) pain spot point line multi-axis TV photography and com- mon chest photos in the frame occult fracture. Methods We randomly selected 120 cases diagnosed as clear frame fracture, and divided them into three groupa Group I with 40 cases was randomly chosen for our film archive type cases. 40 cases in the second group were not clear cases from primary hospital diagnosis ; the third group with 40 cases used the application of Shimadzu D- ision plus-50 pain spot localization method TV photography.Results The application of Shimadzu D-vision plus-50 pain spot mark multi-axis a TV photography for frame fracture diagnosis had the accuracy rate reaching as high as 97. 33%, obviously superior to the group 1 of 81.25%, much better than that of the second group as 67.69%. Conclusions The clinical diagnosis accuracy rate of the multifunctional digital perspective photography system with fixed point multi-axis a TV photography is obviously higher than that of the other two groups, having incomparable superiority in the diagnosis for frame occult fracture.
Keywords:Fixed-point photography  Multi-axis  Frame occult fracture  Penetrated DR