血管回声跟踪技术对兔颈动脉弹性的定量评价研究
引用本文:张莉,金仲群,王建华,王杰超,董风群,王宏宇. 血管回声跟踪技术对兔颈动脉弹性的定量评价研究[J]. 中华超声影像学杂志, 2008, 17(7): 627-630
作者姓名:张莉  金仲群  王建华  王杰超  董风群  王宏宇
作者单位:1. 石家庄市中心医院超声科石家庄市血管疾病研究所,050011
2. 北京军区总医院超声科
3. 河北省老年病医院急诊科
4. 河北省儿童医院超声科
5. 北京大学人民医院心内科
基金项目:河北省科技攻关项目,河北省自然科学基金 
摘    要:目的 探讨探头支架辅助的回声跟踪(echo-tracking,ET)技术定量评价早期动脉硬化的可行性、准确性及各弹性参数的敏感性.方法 对39只4月龄健康新西兰白兔随机分为4组,造模1、2、3组及对照组.造模组均饲喂高脂颗粒饲料,对照组饲喂基础颗粒饲料,分别在喂养的0、4、8、12周末,利用探头支架辅助的ET技术测量颈动脉弹性的各项指标:压力-应变弹性系数(Ep)、僵硬度(β)及顺应性(AC)、脉搏波速度(PWV)、膨大指数(AI)等,同时取兔耳缘静脉血进行血脂检查及颈总动脉病理检查,进行对照分析.结果 Ep、β随造模时间的延长逐渐增加,AC随造模时间的延长逐渐减小,造模4周末与基础状态相比、造模8周末与造模4周末相比、造模12周末与造模8周末相比均出现显著变化,差异均有统计学意义(P<0.05);PWV于造模8周末开始较基础状态增高(P<0.05),于造模12周末显著增高且较造模8周末亦显著增高,差异有统计学意义(P<0.01);AI始终无明显变化.结论 ET技术可准确、可靠地评价早期动脉硬化的动脉弹性,而应用探头支架可保持检查过程的稳定性和结果的敏感性、精确性及可重复性.

关 键 词:超声检查  颈动脉  动脉硬化    回声跟踪技术

Quantitative analysis with echo-tracking technology equipped with probe maintenance tool on carotid elasticity in rabbits
ZHANG Li,JIN Zhong-qun,WANG Jian-hua,WANG Jie-chao,DONG Feng-qun,WANG Hong-yu. Quantitative analysis with echo-tracking technology equipped with probe maintenance tool on carotid elasticity in rabbits[J]. Chinese Journal of Ultrasonography, 2008, 17(7): 627-630
Authors:ZHANG Li  JIN Zhong-qun  WANG Jian-hua  WANG Jie-chao  DONG Feng-qun  WANG Hong-yu
Abstract:Objective To investigate the feasibility, accuracy and senaitivety of echo tracking (ET) technology on carotid elasticity in rabbits. Methods Thirty-nine healthy New Zealand rabbits were divided into 4 groups,which group 1,2,3 were experimental groups and group 4 was control group. Experimental groups were fed with high cholesterol diet,control group were fed with basic diet. The parameters of elasticity of carotid were measured with ET technology, including pressure-strain elasticity modulus(Ep), stiffness parameter(β), arterial complianee(AC), pulse wave velocity( PWV), augmentation index (AI) at the interval of 0,4,8,12 weeks of the experiment respectively. Blood-fat level of all rabbits were checked and the common carotid artery was examined pathologically,which were compared and analyzed then. Results With the prolong of the experiment time,the Ep and β raised, but the AC reduced. There were significant difference between experimental group 1 (4 weeks) and basement,which were same between experimental group 2 (8 weeks) and experimental group 1, between experimental group 3(12 weeks) and experimental group 2( P<0.05). PWV increased comparing with basement in the end of 8 weeks,which increased obviously in the end of 12 weeks,meanwhile was higher than in the end of 8 weeks,which there were significant differences ( P<0.01 ). AI had no change all the time. Conclusions ET technology is accurate and reliable in detecting early atherosclerosis. Probe maintenance tool can keep the steady of checking progress, sensitive of result and repeatability.
Keywords:Ultrasonography  Carotid arteries  Arteriosclerosis  Rabbits  Echo-tracking technique