Relationship between Renying pulse augmentation index and Cunkou pulse condition in different blood pressure groups
Authors:Jiewei Luo  Xingyu Zheng  Zijing Hu  Jing Wu  Shichao Wei  Zhencheng Ye  Weiji Chen  Ning Lin  Jianwei Li
Institution:1. Department of Traditional Chinese Medicine, Fujian Provincial Hospital, Fujian Medical University, Fuzhou 350001, China;2. Department of Ultrasonic Diagnosis, Fujian Provincial Hospital, Fuzhou 350001, China
Abstract:

Objective

To explore the relationship between Renying pulse (carotid) augmentation index (AI) and Cunkou pulse condition in different blood pressure groups, and the clinical significance of Renying and Cunkou pulse parameters to reflect vascular function.

Methods

Eighty-six patients with essential hypertension (EH) and 52 individuals with normal blood pressure (control group) between September 2010 and January 2012 were included in this study. Renying pulse AI was examined by a new diagnostic tool (ALOKA ProSound Alpha 10) — wave intensity (WI) that is calculated as the product of the derivatives of the simultaneously recorded blood pressure changes (dP/dt) and blood-flow-velocity changes (dU/dt), while Cunkou pulse condition was detected by DDMX-100 Pulse Apparatus in both EH and control groups. A multifactorial correlation analysis was performed for data analysis.

Results

After adjusting for potential confounding variables, in the EH group, AI was positively correlated with t5, w2/t (rt5=0.225, P<0.05; rw2/t=0.230, P< 0.05) and negatively correlated with h5, h5/h1 and w2 (rh5= − 0.393, P<0.01; rh5/h1= − 0.444, P<0.01; rw2= − 0.389, P<0.01). In the control group, AI was positively correlated with t3, t4, t5 and w1 (rt3=0.595, P<0.01; rt4= 0.292, P<0.05; rt5=0.318, P<0.05; rw1=0.541, P<0.01) and negatively correlated with h1, h2, h3, Ad and A (rh1= − 0.368, P<0.05; rh2= − 0.330, P<0.05; rh3= − 0.327, P< 0.05; rAd= − 0.322, P<0.05; rA= − 0.410, P<0.01). In the total sample group (EH plus control group, n= 138), AI was positively correlated with t, t5, w1 and w2/t (rt=0.257, P<0.01; rt5=0.266, P<0.01; rw1=0.184, P< 0.05; rw2/t=0.210, P<0.05) and negatively correlated with h5, h5/h1, w2 and Ad (rh5= − 0.230, P<0.01; rh5/h1= − 0.218, P<0.05; rw2= − 0.267, P<0.01; rAd= - 0.246, P<0.01). Multiple linear regression analysis was carried out to model the relationship (F=7.887, P< 0.001).

Conclusion

Renying pulse AI can effectively predict arterial stiffness in synchrony with the manifestations of Cunkou pulse in elderly patients with hypertension. Cunkou pulse apparatus is a valuable tool for evaluating AI in clinical practice. The close correlations reported above reflect the holistic concept of Traditional Chinese Medicine.
Keywords:Ultrasonography  Hypertension  essential  Cunkou pulse diagnosis  Renying pulse  Augmentation index  Wave intensity