经骶1-2侧块螺钉与骶1前外骶骨翼螺钉的比较研究
引用本文:尤传飞,袁峰,陈宏亮,邱维胜,李林东,裴儒,徐雷军. 经骶1-2侧块螺钉与骶1前外骶骨翼螺钉的比较研究[J]. 徐州医学院学报, 2014, 0(9): 607-610
作者姓名:尤传飞  袁峰  陈宏亮  邱维胜  李林东  裴儒  徐雷军
作者单位:1. 泗阳县人民医院骨一科,江苏 泗阳,223700
2. 徐州医学院附属医院骨科,江苏 徐州,221002
摘    要:目的:通过测量经骶1-2侧块螺钉与骶1前外骶骨翼螺钉的钉道长度和最大拔出力,比较两者的固定效果。方法对27例(男14例,女13例)骶尾椎CT检查的影像学资料进行三维重建,利用Advantage worksta-tion 4.2后处理工作站软件测量经骶1-2侧块螺钉与骶1前外骶骨翼螺钉的钉道长度。取8具甲醛溶液固定的湿润成人骶骨标本,采用双能X线吸收测定仪测定骶1椎体骨密度,记录其平均值。在同一骶骨标本左右侧分别随机植入经骶1-2侧块螺钉和骶1前外骶骨翼螺钉。将标本固定于858型MTS材料试验机上,对螺钉施加轴向拔出力,计算最大拔出力。结果经骶1-2侧块螺钉平均钉道长度为(53.78±3.02) mm,骶1前外骶骨翼螺钉为(44.73±2.59)mm,差异有统计学意义(P<0.05)。经骶1-2侧块螺钉即刻平均最大拔出力为(379.62±73.10) N,骶1前外骶骨翼螺钉为(230.62±98.52)N,差异有统计学意义(P<0.05)。结论经骶1-2侧块螺钉固定的钉道长度及最大拔出力均优于骶1前外骶骨翼螺钉,可作为临床上一种有效的选择。

关 键 词:骶骨  侧块  螺钉内固定  解剖学  生物力学

A comparative study of S1-2 lateral mass screws and anterolateral S1 sacrum alae screws
YOU Chuanfei,YUAN Feng,CHEN Hongliang,QIU Weisheng,LI Lindong,PEI Ru,XU Leijun. A comparative study of S1-2 lateral mass screws and anterolateral S1 sacrum alae screws[J]. Acta Academiae Medicinae Xuzhou, 2014, 0(9): 607-610
Authors:YOU Chuanfei  YUAN Feng  CHEN Hongliang  QIU Weisheng  LI Lindong  PEI Ru  XU Leijun
Affiliation:YOU Chuanfei, YUAN Feng, CHEN Hongliang, QIU Weisheng, LI Lindong, PEI Ru, XU Leijun (1. Department of Orthopedics, the People's Hospital of Siyang County, Jiangsu 223700, China; 2. Department of Orthopedics, the Affiliated Hospital of Xuzhou Medical College, Xuzhou, Jiangsu 221002)
Abstract:Objective To compare the effects of S 1-2 lateral mass screws and anterolateral S 1 sacrum alae screws by measuring the maximal length and pull -out force.Methods CT images of the sacrum were collected from 27 pa-tients (14 men and 13 women) to perform three-dimensional reconstruction .Using the Advantage Workstation ( AW) 4.2 software, the maximal lengths were measured for S1-2 lateral mass screws and anterolateral S1 sacrum alae screws. Eight adult cadaver specimens fixed in formalin were adopted to examine the bone mineral density of S 1 vertebral using dual-energy x-ray absorptiometry (DEXA).After randomly implanted with S1-2 lateral mass screws and anterolater-al S1 sacrum alae screws on both sides , the specimens were placed on a MTS 858 bio-nix testing machine to record the maximal pull-out force .Results Statistical differences were found in the average maximal length between S 1-2 lateral mass screws [(53.78 ±3.02) mm, P〈0.05] and anterolateral S1 sacrum alae screws [(44.73 ±2.59) mm, P〈0.05)].The average maximal pull -out force was 379.62 ±73.10 N for S1-2 lateral mass screws, which was signifi-cantly different from that of anterolateral S1 sacrum alae screws [(230.62 ±98.52) N, P〈0.05].Conclusion S1-2 lateral mass screws are superior to anterolateral S 1 sacrum alae screws in terms of the maximal length and pull -out force, indicating its promising use in clinical setting .
Keywords:sacrum  lateral mass  screw fixation  anatomy  biomechanics