首页 | 本学科首页   官方微博 | 高级检索  
     


Antibodies to factor VIII in plasma of patients with hemophilia A and normal subjects
Authors:J. Batlle  E. Gömez  E. Rendal  J. Torea  E. Lourés  M. Couselo  P. Vila  C. Sedano  X. Tusell  M. Magallönö  M. Quintana  R. González-Boullosa  M. F. Löpez-Fernández
Affiliation:1. Department of Hematology, Hospital Juan Canalejo-Teresa Herrera, and Department of Medicine, University of Santiago, Carretera del Pasaje s/n, E-15006, La Coru?a, Spain
2. Department of Hematology, Hospital Santa Maria Madre, Orense, Spain
3. Department of Hematology, Hospital de Valdecilla, Santander, Spain
4. Department of Hematology, Unitat d’Haemofilia, Hospital Vall d’Hebrón, Barcelona, Spain
5. Department of Hematology, Hospital La Paz, Madrid, Spain
6. Department of Hematology, Hospital Xeral, Vigo, Spain
Abstract:
 Non-neutralizing factor VIII (FVIII) antibodies (FVIII-Ab) in hemophilia A may be associated with an abnormal clinical response to FVIII concentrates. Patients with FVIII inhibitors may develop noncoagulation FVIII-Ab after the induction of immunotolerance. Natural FVIII-Ab may be detected in the plasma of some healthy subjects. The aim of this study was to analyze the presence of FVIII-Ab in the plasma of 53 normal blood donors and 124 patients with hemophilia A (18 patients had a previous history of FVIII inhibitor, but only 12 had inhibitor at the moment this study was performed). FVIIII inhibitor was measured using the Bethesda method. FVIII-Ab were analyzed by a specific ELISA assay using purified FVIII from a monoclonal concentrate and a standard plasma containing 26 Bethesda units (BU) of FVIII inhibitor. Purified FVIII was used to coat wells of a microtiter plate and was incubated with dilutions of plasma to be tested. Bound human IgG FVIII-Ab were detected by incubation with polyclonal sheep anti.human IgG alkaline phosphatase conjugate, and the OD405 was quantitated. A linear fit was obtained (by plotting FVIII-Ab positivity [OD 405nm] versus BU titer) when serial dilutions of this standard inhibitor plasma, containing titers of 0.5 BU or higher, were used. Four different levels of FVIII-Ab positivity [OD 405nm] were distinguished in this assay: Negative levels (–) were obtained with dilutions of the standard inhibitor containing <0.5 BU. Mild levels (+) were obtained with dilutions of 0.5–5 BU. Moderate levels (++) were obtained for dilutions ranging from 5–25 BU. Maximum positivity (+++) was obtained for dilutions of titers > 25 BU. FVIII-Ab positivity was detected in eight of the normal subjects (15%): three were found to be moderately positive (++) and five mildly positive (+). No inhibitory activity was detectable when whole plasma was used. All the hemophilic patients with a presence of FVIII inhibitor at the time of the study were found to be positive for FVIII-Ab. In addition, the level of positivity correlated with the corresponding BU. Four of the six patients who had a history of inhibitor were negative and two positive. Twenty additional patients (16.12%) in whom no inhibitory activity was detected were found to be positive for FVIII-Ab: 16 + and four ++. The mean age of patients with FVIII-Ab positivity was significantly higher than that of patients of the FVIII-Ab negative group (p<0.005). In conclusion, FVIII-Ab positivity in patients with hemophilia A was 17.7% higher than the level of positivity detected by an inhibitory assay. We propose that this method for FVIII-Ab analysis could be used for patients with hemophilia A, at least to complement the functional inhibitor assay. FVIII recovery or half-life should be assessed in patients who test positive for FVIII-Ab and who show no evidence of inhibitor. Received: 31 July 1995 / Accepted: 25 January 1996
Keywords:  FVIII antibodies  Hemophilia  Inhibitors  FVIII  HIV
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号