首页 | 本学科首页   官方微博 | 高级检索  
     


3.0 Tesla vs 1.5 Tesla breast magnetic resonance imaging in newly diagnosed breast cancer patients
Authors:Reni S Butler  Christine Chen  Reena Vashi  Regina J Hooley  Liane E Philpotts  
Affiliation:Reni S Butler, Christine Chen, Reena Vashi, Regina J Hooley, Liane E Philpotts, Department of Diagnostic Radiology, Yale University School of Medicine, New Haven, CT 06437, United StatesReena Vashi, Department of Diagnostic Radiology, Memorial Hermann Healthcare System, Houston, TX 77074, United States
Abstract:AIM: To compare 3.0 Tesla (T) vs 1.5T magnetic resonance (MR) imaging systems in newly diagnosed breast cancer patients.METHODS: Upon Institutional Review Board approval, a Health Insurance Portability and Accountability Act-compliant retrospective review of 147 consecutive 3.0T MR examinations and 98 consecutive 1.5T MR examinations in patients with newly diagnosed breast cancer between 7/2009 and 5/2010 was performed. Eleven patients who underwent neoadjuvant chemotherapy in the 3.0T group were excluded. Mammographically occult suspicious lesions (BIRADS Code 4 and 5) additional to the index cancer in the ipsilateral and contralateral breast were identified. Lesion characteristics and pathologic diagnoses were recorded, and results achieved with both systems compared. Statistical significance was analyzed using Fisher’s exact test.RESULTS: In the 3.0T group, 206 suspicious lesions were identified in 55% (75/136) of patients and 96% (198/206) of these lesions were biopsied. In the 1.5T group, 98 suspicious lesions were identified in 53% (52/98) of patients and 90% (88/98) of these lesions were biopsied. Biopsy results yielded additional malignancies in 24% of patients in the 3.0T group vs 14% of patients in the 1.5T group (33/136 vs 14/98, P = 0.07). Average size and histology of the additional cancers was comparable. Of patients who had a suspicious MR imaging study, additional cancers were found in 44% of patients in the 3.0T group vs 27% in the 1.5T group (33/75 vs 14/52, P = 0.06), yielding a higher positive predictive value (PPV) for biopsies performed with the 3.0T system.CONCLUSION: 3.0T MR imaging detected more additional malignancies in patients with newly diagnosed breast cancer and yielded a higher PPV for biopsies performed with the 3.0T system.
Keywords:Breast   Breast cancer   Cancer staging   Outcome   Magnetic resonance imaging   Breast magnetic resonance imaging   3 Tesla   Technical
本文献已被 CNKI 等数据库收录!
点击此处可从《World journal of radiology》浏览原始摘要信息
设为首页 | 免责声明 | 关于勤云 | 加入收藏