首页 | 本学科首页   官方微博 | 高级检索  
检索        

GC-MS法测定盐酸金霉素眼膏中16种多环芳烃含量
引用本文:肖钦钦,刘绪平,段和祥,陈希,张银花.GC-MS法测定盐酸金霉素眼膏中16种多环芳烃含量[J].中国抗生素杂志,2019,44(3):383-388.
作者姓名:肖钦钦  刘绪平  段和祥  陈希  张银花
作者单位:江西省药品检验检测研究院江西省药品与医疗器械质量工程技术研究中心
摘    要:目的建立盐酸金霉素眼膏中16种多环芳烃(PAHs)的气相色谱-质谱含量测定方法。方法盐酸金霉素眼膏经正己烷溶解后,用正己烷饱和乙腈多次萃取,浓缩后经GC-MS法检测,气相色谱采用DB-5MS毛细管柱,程序升温,进样口温度250℃,质谱采用电子轰击(EI)离子源,以选择反应监测(SIM)模式进行检测。同时从辅料来源及生产工艺上分析制剂中PAHs异常的主要原因。结果 16种PAHs在相应浓度范围内线性关系良好,定量限(LOQ)为0.3~20.0ng/mL,回收率为72%~118%,相对标准偏差(RSD)均小于2.5%,辅料凡士林的质量直接影响制剂的好坏。结论本法准确度高、灵敏度强,适用于盐酸金霉素眼膏中PAHs的检测,可为眼膏剂的质量控制与安全性评估提供数据参考。

关 键 词:盐酸金霉素眼膏  多环芳怪(PAHs)  气相色谱-质谱  安全性评估

Determination of 16 polycyclic aromatic hydrocarbons in chlortetracycline hydrochloride eye ointment by GC-MS
Xiao Qin-qin,Liu Xu-ping,Duan He-xiang,Chen Xi,Zhang Yin-hua.Determination of 16 polycyclic aromatic hydrocarbons in chlortetracycline hydrochloride eye ointment by GC-MS[J].Chinese Journal of Antibiotics,2019,44(3):383-388.
Authors:Xiao Qin-qin  Liu Xu-ping  Duan He-xiang  Chen Xi  Zhang Yin-hua
Institution:(Jiangxi Institute for Drug Control. Jiangxi Province Engincering Research Center of Drug and Medical Device Quality. Nanchang 330029)
Abstract:Objective To establish a method for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in chlortetracycline hydrochloride eye ointment by gas chromatography-mass spectrometry. Methods Chlortetracycline hydrochloride eye ointment was dissolved in n-hexane and extracted by acetonitrile saturated with n-hexane for many times. After concentration, it was detected by GC-MS. GC analysis was performed on the DB-5MS capillary column with the inlet temperature at 250℃ and the programmed column temperature was used. Mass spectrometry was analyzed under the selective reaction monitoring (SIM) mode by electron bombardment (EI) ion source. In addition, the main causes of PAHs abnormality were studied from the source of excipients and the technological process of production. Results The linear relationships of all compounds were good with the corresponding concentration range, the limits of quantitation (LOQs) of PAHs were 0.3~20.0ng/mL. The recoverieswere found to be from 72% to 118% with relative standard deviation (RSD) lower than 2.5%. The quality of vaseline directly affected the quality of the preparation. Conclusion This method is accurate and sensitive, and is suitable for the detection of PAHs in chlortetracycline hydrochloride eye ointment. This study can provide a data reference for the quality control and safety assessment of eye
Keywords:Chlortetracycline hydrochloride eye ointment  Polycyclic aromatic hydrocarbons (PAHs)  Gas chromatography-mass spectrometer  Safety assessment  
本文献已被 维普 等数据库收录!
点击此处可从《中国抗生素杂志》浏览原始摘要信息
点击此处可从《中国抗生素杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏