摘    要:目的:对采用压差法测量医用气体流量的测量原理、结构和工艺等因素引入的不确定度进行分析.方法:利用液体流经节流装置时所产生的压差测量气体流量.结果:合成不确定度μc=1.364%,满足产品设计要求.结论:压差传感器测量方法准确可靠,能够满足对医用气体流量测量的要求.

关 键 词:压差传感器  气体流量  不确定度

Uncertainty analysis on using pressure difference sensor for flow measurement
SHANG Hong-tao,TANG Hui. Uncertainty analysis on using pressure difference sensor for flow measurement[J]. China Medical Equipment, 2014, 0(8): 45-46
Authors:SHANG Hong-tao  TANG Hui
Affiliation:(Medical Engineering Department of General Hospital Under Beijing Area Command, Beijing 100700, China)
Abstract:Objective:The uncertainty from the principle,structure and technology of measuring the flow with pressure difference method is analyzed.Methods:The quantity of flow was calculated using the pressure differential data determined by throttling gear when it flowing.Results:Composite uncertainty is 1.364%,which satisfied the product design demands.Conclusion:This method which is accurate and reliable can meet the requirement of measuring the gas flow.