Comparison of predictive performance for toxicity by accumulative dose of DVH parameter addition and DIR addition for cervical cancer patients
Authors:Yuya Miyasaka  Noriyuki Kadoya  Rei Umezawa  Yoshiki Takayama  Kengo Ito  Takaya Yamamoto  Shohei Tanaka  Suguru Dobashi  Ken Takeda  Kenji Nemoto  Takeo Iwai  Keiichi Jingu
Institution:Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan;Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan;Kanagawa Cancer Center, Yokohama, Japan;Course of Radiological Technology, Health Sciences, Tohoku University Graduate School of Medicine, Sendai, Japan;Department of Radiology, Yamagata University Faculty of Medicine, Yamagata, Japan
Abstract:We compared predictive performance between dose volume histogram (DVH) parameter addition and deformable image registration (DIR) addition for gastrointestinal (GI) toxicity in cervical cancer patients. A total of 59 patients receiving brachytherapy and external beam radiotherapy were analyzed retrospectively. The accumulative dose was calculated by three methods: conventional DVH parameter addition, full DIR addition and partial DIR addition. , and (minimum doses to the most exposed 2 cm3, 1cm3 and 0.1 cm3 of tissue, respectively) of the rectum and sigmoid were calculated by each method. V50, V60 and V70 Gy (volume irradiated over 50, 60 and 70 Gy, respectively) were calculated in full DIR addition. The DVH parameters were compared between toxicity (≥grade1) and non-toxicity groups. The area under the curve (AUC) of the receiver operating characteristic (ROC) curves were compared to evaluate the predictive performance of each method. The differences between toxicity and non-toxicity groups in were 0.2, 5.7 and 3.1 Gy for the DVH parameter addition, full DIR addition and partial DIR addition, respectively. The AUCs of were 0.51, 0.67 and 0.57 for DVH parameter addition, full DIR addition and partial DIR addition, respectively. In full DIR addition, the difference in dose between toxicity and non-toxicity was the largest and AUC was the highest. AUCs of V50, V60 and V70 Gy were 0.51, 0.63 and 0.62, respectively, and V60 and V70 were high values close to the value of of the full DIR addition. Our results suggested that the full DIR addition may have the potential to predict toxicity more accurately than the conventional DVH parameter addition, and that it could be more effective to accumulate to all pelvic irradiation by DIR.
Keywords:cervical cancer  brachytherapy  deformable image registration  dose accumulation  GI toxicity
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号