Diagnosis of progressive compression of the aortic true lumen with intraoperative transesophageal echocardiography during repair of dissection of thoracic aorta--a case report
Authors:Hong C L  Ho A C  Liu H P  Chung H S  Chen C H  Tso A S  Yang M W
Abstract:We report an incident of progressive compression of the true lumen of aorta which happened immediately after cardiopulmonary bypass (CPB) and was diagnosed with intraoperative transesophageal echocardiography (TEE) in a patient undergoing an emergent repair of type A aortic dissection under femoral perfusion. During the CPB period, intraoperative TEE revealed gradual expansion of the false lumen which nearly obstructed the true lumen of the dissected aorta. The possible mechanism was related with distension of the false lumen by a dominant flow from retrograde femoral perfusion of CPB. With the application of intraoperative TEE, we could easily detect the hemodynamic changes of thoracic aorta and find the real causes so as to solve the perfusion abnormalities.