首页 | 本学科首页   官方微博 | 高级检索  
     


Ischaemia induced alternans of action potential duration in the intact-heart: dependence on coronary flow, preload and cycle length
Authors:KURZ, R. W.   MOHABIR, R.   REN, X.-L.   FRANZ, M. R.
Affiliation:First Medical Department Donauspital, Vienna, Austria
*Cardiovascular Medicine Division, Falk Cardiovascular Research Center, Stanford University School of Medicine Stanford, CA, U.S.A.
"{dagger}"Pharmacology Department, School of Medicine, Georgetown University Washington, DC, U.S.A.
Abstract:Clinical and experimental evidence relate action potential duration(APD) alternans to ischaemic heart disease and ventricular arrhythmias.The present investigation was performed to study the quantitativerelationship between APD alternans and the degree ofischaemia,loading conditions and cycle length (CL) in an intact heart. Monophasic action potentials (MAP) were simultaneously recordedby contact electrodes from two left (LV) undone right ventricular(RV) sites in 20 Langendorff-perfused rabbit hearts. The preparationswere subjected to global ischaemia at flow rates ranging from40% of normal flow to complete cessation of flow. Pacing wasperformed at either constant or regularly changing CL. The magnitudeof APD alternans was expressed as beat-to-beat differences inaction potential duration of two consecutive MAPs. During normalper fusion, neither very fast pacing at a CL of 200 ms nor periodicalrate switches resulted in persistent APD alternans. Pacing ata constant CL of 800 ms did not induce A PD alternans at completecessation of flow for 6 min. However, alternans developed progressivelyat a constant CL of 400 ms after 2.8±0.3 min of completeischaemia at the pre-loaded LV, andafter 4.6±0.4 minat the unloaded RV (P<0.01). The reduction of preload atthe LV from 15 to 5 mmftg end-diastolic pressure delayed developmentof APD alternans from 2.8±0.3 min to 4.3±0.4 min(P < 0.05) at 400 ms CL. Following graded under per fusionof 40%, 20% and 10% of initial flow, persistent APD alternansdeveloped in relation to the degree of flow reduction and increasedprogressively with duration ofischaemia. APD alternans at theLV always preceded the onset of APD alternans at the RV. Inexperiments with identical flow rates the shortest CL of 200ms resulted in the greatest and earliest initiation of APD alternanscompared to the longer CL (P<0.01, P<0.001). An increasein CL from 400 to 800 ms immediately abolished APD alternans,generated by the shorter CL, at any time during the 6 min periodof complete ischaemia. Similarly, increasing the cycle lengthfrom 200 or 400 to 600 ms eliminated APD alternans up to 6 minof ischaemia and significantly reduced its magnitude between7 and 10 min within a few beats. We conclude that persistent APD alternans is a characteristicfinding in the rabbit heart during global ischaemia. It is asensitive parameter of the severity of ischaemia and dependson the degree and duration of ischaemia as well as on the preload.The CL appears to have an independent effect on the generationof APD alternans, which is functionally separate from the effectof CL on the ischaemic burden. An eventual impact of these observationscould be the application of APD alternans as a diagnostic toolin electrophysiological examinations of myocardial ischaemiain experimental and clinical settings.
Keywords:Alternans    action potential duration    ischaemia    monophasic action potentials    contact electrodes    Langendorff preparation
本文献已被 Oxford 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号