首页 | 本学科首页   官方微博 | 高级检索  
     


An improved and fully validated LC-MS/MS method for the simultaneous quantification of simvastatin and simvastatin acid in human plasma
Authors:Apostolou Constantinos  Kousoulos Constantinos  Dotsikas Yannis  Soumelas Georgios-Stefanos  Kolocouri Filomila  Ziaka Afroditi  Loukas Yannis L
Affiliation:Laboratory of Pharmaceutical Analysis and Bioequivalence Services (GLP Compliant), Department of Pharmaceutical Chemistry, School of Pharmacy, University of Athens, Panepistimioupoli Zografou GR 157 71, Athens, Greece.
Abstract:A fully automated high-throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous quantification of simvastatin (SV) and simvastatin acid (SVA) in human plasma. Plasma samples were treated by acetonitrile (ACN) addition for protein precipitation (PP) and subsequent two-step liquid-liquid extraction (LLE) in 96-deepwell plates, using methyl t-butyl ether (MTBE) as the organic solvent. ACN addition step was proven to enhance method sensitivity, as well as producing cleaner samples for injection. Lovastatin (LV) and lovastatin acid (LVA) were used as internal standards (IS) for SV and SVA quantification respectively. A relatively small plasma volume (300 microL) was employed and all procedure liquid transfer steps were performed automatically, by the use of robotic liquid handling workstations. Both electrospray (ESI) and atmospheric pressure chemical ionization (APCI) sources were applied and compared for LC-MS/MS sample analysis, with ESI proven to be more sensitive for the specific analytes. Polarity switch (from negative to positive ionization mode) was performed during the same analytical run, so as for the simultaneous SV and SVA determination to be possible. The method had a short sample preparation time, as well as a chromatographic run time of just 1.9 min, the shortest so far reported for SV determination. It was validated and fulfilled all preset criteria for sensitivity, specificity, linearity (0.100-40.0 ng/mL), inter- and intra-accuracy and precision for both molecules. The proposed method was applied to the rapid and reliable simultaneous determination of SV and SVA in a bioequivalence study, after per os administration of a SV tablet (80 mg).
Keywords:Simvastatin   Bioequivalence   96-Well   Electrospray   Two-step extraction   Polarity switch
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号