首页 | 本学科首页   官方微博 | 高级检索  
检索        

3.0T磁共振在臂丛神经成像中的应用研究
引用本文:吕银章,孔祥泉,刘定西,柳曦,杨帆,罗是是,常丹丹,曹桢斌.3.0T磁共振在臂丛神经成像中的应用研究[J].中华手外科杂志,2011,27(3).
作者姓名:吕银章  孔祥泉  刘定西  柳曦  杨帆  罗是是  常丹丹  曹桢斌
作者单位:华中科技大学同济医学院附属协和医院放射科,武汉,430022
摘    要:目的 探讨3.0T磁共振扫描仪3D-STIR序列增强扫描在臂丛神经成像中的可行性,以及临床应用的效果和价值.方法 对26例志愿者及35例臂丛神经病变的患者,采用3.0T磁共振成像(MRI)常规扫描序列、3D-STIR序列平扫及3D-STIR序列增强扫描,观察所得图像,评价显示情况和对比噪声比.结果 3.0T MRI 3D-STIR序列及其增强扫描可清楚明确地显示所有志愿者臂丛神经的构成、走行、连续性、形态及信号,可以清楚地显示外伤或肿瘤累及臂丛神经所致的各种征象.结论 3.0T磁共振扫描仪3D-STIR序列增强扫描对臂丛神经病变的诊断和治疗有非常重要的价值.
Abstract:
Objective To investigate the feasibility of imaging brachial plexus in enhanced scan of 3D-STIR sequence in 3.0T MRI and the practical value of clinical application. Methods Twenty-six healthy volunteers and 35 patients with brachial plexus lesions underwent imaging of the brachial plexus with 3.0T MRI conventional scanning sequence,3D-STIR sequence scanning and 3D-STIR sequence of enhanced scan. The obtained images were observed to evaluate the image quality and signal to noise ratio. Results 3D-STIR sequence and enhanced scan could clearly display the components,course,continuity,shape and signals of the brachial plexus in all the healthy volunteers. The enhanced scan could improve the suppression effects of the background,and therefore could clearly visualize trauma and tumor involving the brachial plexus due to a variety of signs. Conclusion 3.0T MRI enhanced scan of 3D-STIR sequence has potential values in the diagnosis and treatment of brachial plexus diseases.

关 键 词:磁共振成像  臂丛  磁共振神经成像

Application of 3.0T MRI in imaging of the brachial plexus
LU Yin-zhang,KONG Xiang-quan,LIU Ding-xi,LIU Xi,YANG Fan,LUO Shi-shi,CHANG Dan-dan,CAO Zhen-bin.Application of 3.0T MRI in imaging of the brachial plexus[J].Chinses Journal of Hand Surgery,2011,27(3).
Authors:LU Yin-zhang  KONG Xiang-quan  LIU Ding-xi  LIU Xi  YANG Fan  LUO Shi-shi  CHANG Dan-dan  CAO Zhen-bin
Abstract:Objective To investigate the feasibility of imaging brachial plexus in enhanced scan of 3D-STIR sequence in 3.0T MRI and the practical value of clinical application. Methods Twenty-six healthy volunteers and 35 patients with brachial plexus lesions underwent imaging of the brachial plexus with 3.0T MRI conventional scanning sequence,3D-STIR sequence scanning and 3D-STIR sequence of enhanced scan. The obtained images were observed to evaluate the image quality and signal to noise ratio. Results 3D-STIR sequence and enhanced scan could clearly display the components,course,continuity,shape and signals of the brachial plexus in all the healthy volunteers. The enhanced scan could improve the suppression effects of the background,and therefore could clearly visualize trauma and tumor involving the brachial plexus due to a variety of signs. Conclusion 3.0T MRI enhanced scan of 3D-STIR sequence has potential values in the diagnosis and treatment of brachial plexus diseases.
Keywords:Magnetic resonance imaging  Brachial plexus  Magnetic resonance neurography
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号