首页 | 本学科首页   官方微博 | 高级检索  
检索        

生脉注射液工艺改进前后类过敏反应比较
引用本文:易艳,李春英,唐仁茂,王云庭,赵雍,李桂琴,秦林,丛旭东,梁爱华.生脉注射液工艺改进前后类过敏反应比较[J].中国中药杂志,2012,37(13):1875-1879.
作者姓名:易艳  李春英  唐仁茂  王云庭  赵雍  李桂琴  秦林  丛旭东  梁爱华
作者单位:1. 中国中医科学院中药研究所,北京,100700
2. 江苏苏中药业集团股份有限公司,江苏姜堰,225500
3. 中国中医科学院中药研究所,北京100700;首都医科大学中医药学院,北京100069
基金项目:国家"重大新药创制"科技重大专项(2009ZX09301-005,2009ZX09502-001);国家科技支撑计划项目(2006BAI14B05);中国中医科学院自选课题(2009年度)
摘    要:目的:比较生脉注射液工艺改进前后对动物的类过敏反应的差异,以探讨提高生脉注射液安全性的可能性。方法:小鼠耳廓血管通透性分析:将ICR小鼠随机分成不同实验组,分别一次性静脉注射含有0.4%伊文思蓝(EB)的5%葡萄糖注射液、Compound 48/80溶液或工艺改进前后的不同浓度生脉注射液。给药后30 min记录各组动物耳廓血管通透性增高反应的阳性率,进行耳廓蓝染程度评分,并定量测定耳廓伊文思蓝渗出量。大鼠皮肤血管通透性试验:即动物先静脉注射给予0.6%伊文思蓝生理盐水溶液,10 min后再从背部皮内注射给予上述受试物,每个点注射50μL药液,20 min后处死大鼠,测量皮肤内的蓝色斑点大小,并定量测定其中伊文思蓝渗出量。结果:生脉注射液原工艺16.7 mL.kg-1组(相当于临床剂量的1.67倍剂量)的小鼠可见耳廓血管通透性明显增高,而10 mL.kg-1的生脉注射液(相当于临床等倍剂量)组未见明显的耳廓血管通透性增高;新工艺16.7 mL.kg-1组的耳廓通透性增高程度较相同剂量原工艺组明显减轻。原工艺生脉注射液皮内注射后,在注射部位导致明显的渗出、水肿,从而形成较大的蓝斑,有一定剂量关系。新工艺在注射局部也可造成一定程度的蓝斑,但蓝斑直径较原工艺组减小,皮肤伊文思蓝渗出量减少,说明新工艺的皮肤类过敏反应较轻。结论:生脉注射液原工艺有明显增高血管通透性的作用,提示有致类过敏作用;改进工艺后其导致血管通透性增高的不良作用减轻,提示改进工艺可减轻类过敏反应。

关 键 词:类过敏反应  生脉注射液  工艺改进  血管通透性
收稿时间:2012/4/18 0:00:00

Comparative study on pseudoanaphylactoid reactions induced by pulse-activating injection before and after improving technology
YI Yan,LI Chunying,TANG Renmao,WANG Yunting,ZHAO Yong,LI Guiqin,QIN Lin,CONG Xudong and LIANG Aihua.Comparative study on pseudoanaphylactoid reactions induced by pulse-activating injection before and after improving technology[J].China Journal of Chinese Materia Medica,2012,37(13):1875-1879.
Authors:YI Yan  LI Chunying  TANG Renmao  WANG Yunting  ZHAO Yong  LI Guiqin  QIN Lin  CONG Xudong and LIANG Aihua
Institution:Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China;Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China;Suzhong Yaoye Group Pharmaceutical Limited, Jiangyan 225500, China;Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China;Capital Medical University, School of Traditional Chinese Medicine, Beijing 100069, China;Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China;Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China;Suzhong Yaoye Group Pharmaceutical Limited, Jiangyan 225500, China;Suzhong Yaoye Group Pharmaceutical Limited, Jiangyan 225500, China;Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China
Abstract:Objective: To investigate a possibility to improve the security of pulse-activating injection by comparing the difference of pseudoanaphylactoid reactions (PR) induced by pulse-activating injection before and after improving technology. Method: The analysis of vascular permeability of the mice's ears: ICR mouse were divided into different test groups, and intravenously injected with solutions of different concentration of pulse-activating injection before and after improving technology, positive control Compound 48/80 and 5% glucose injection. All test substances were mixed with 0.4% Evans blue. The reaction and vascular permeability of the ears were observed and measured 30 min after injection. The vascular permeability of the rat's skin: the rats were intravenous injected with 0.6% Evans blue normal saline solution first, 10 minutes later, the same test substances were intradermal injected into the back of rats, there are 16 injected spots in the back of rat. The rats were sacrificed and the diameter of locus ceruleus and the content of Evans blue leaked out were measured 20 min after injection. Result: Pulse-activating injection before improving technology with dose of 16.7 mL·kg-1(in 1.67 times the clinical dose) caused obvious vascular hyperpermeability in ICR mice. In the group of pulse-activating injection before improving technology with dose of 10 mL·kg-1(in clinic equivalent dose), no obvious vascular hyperpermeability in the ears were observed. The degrees of vascular hyperpermeability in the group of pulse-activating injection after improving technology with dose of 16.7 mL·kg-1 were more lessen than the same dose of injection before improving technology. Pulse-activating injection before improving technology caused obvious exudation, oedema locus ceruleus in the injection site of rat's back,and it showed a certain dose-effect relation. Pulse-activating injection after improving technology caused locus ceruleus in the injection site too, but the diameters of the locus ceruleus were shorter than the diameters in the group of pulse-activating injection before improving technology, and the contents of leaked out Evans blue were fewer. All of these showed that PR of skin induced by pulse-activating injection after improving technology is alleviated. Conclusion: Pulse-activating injection before improving technology cause obvious vascular hyperpermeability, but the same dose of pulse-activating injection after improving technology can't cause obvious vascular hyperpermeability. The result indicated that the pulse-activating injection before improving technology can cause PR, improving technology can lessen the degree of PR induced by the injection.
Keywords:pseudoanaphylactoid reactions  pulse-activating injection  improving technology  vasopermeability
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号