首页 | 本学科首页   官方微博 | 高级检索  
检索        

CT引导下同轴技术肌肉骨骼肿瘤穿刺活检的临床应用
引用本文:娄雪磊,寇志平,张强.CT引导下同轴技术肌肉骨骼肿瘤穿刺活检的临床应用[J].实用医技杂志,2007,14(19):2539-2540.
作者姓名:娄雪磊  寇志平  张强
作者单位:[1]新乡市中心医院,河南新乡453000 [2]新乡市新华医院,河南新乡453000
摘    要:目的:评价应用同轴活检技术,进行CT引导下肌肉骨骼肿瘤穿刺活检的临床应用价值。方法:CT引导下同轴技术穿刺活检肌肉骨骼肿瘤26例,同轴套管针于穿刺点按预定角度、深度快速穿刺,针尖至肿瘤边缘内或近穿刺点1/3处,经同轴套管针置入自动活检针,适度改变同轴套管针方向,不同角度、深度对肿瘤进行切割,取材,固定后行病理学检查。结果:26例患者穿刺成功率100%,病理检查明确诊断率92.3%(24/26),无一例严重并发症。结论:CT引导下同轴技术肌肉骨骼肿瘤穿刺活检,可多次、多点取材,提高阳性率以及正确诊断率,降低并发症发生率,此项技术简便易行,是一种安全、有效的诊断措施。

关 键 词:CT引导  同轴技术  肌肉骨骼肿瘤  穿刺活检术
文章编号:1671-5098(2007)19-2539-02
收稿时间:2007-04-17
修稿时间:2007-04-17

The Clinical Application of CT-guided Muscleorskeleton Tumor Puncture Biopsy with The Co-axle Technique
LOU Xue-lei ,KOU Zhi-ping,ZHANG Qiang.The Clinical Application of CT-guided Muscleorskeleton Tumor Puncture Biopsy with The Co-axle Technique[J].Journal of Practical Medical Techniques,2007,14(19):2539-2540.
Authors:LOU Xue-lei  KOU Zhi-ping  ZHANG Qiang
Institution:1. The Central/Hospital of Xinxiang, Xinxiang, Henan 453000,China; 2.The Xinhua Hospital of Xinxiang, Xinxiang, Henan 453000,China
Abstract:Objective To evaluate the clinical application value of CT-guided muscleorskeleton tumor puncture biopsy with the co-axle transfixion pin biopsy technique . Methods The clinical data of 26 cases of CT-guided muscleorskeleton tumor puncture biopsy with the co-axle transfixion pin biopsy technique . Under the prepared angle and depth puncture quickly in the puncture point using the co-axle casing needle . When the needle reached the edge of tumor or the near 1/3 the puncture point . Implant the automatic biopsy needle through the co-axle casing needle. Moderate change the direction of the co-axle casing needle and making different angle and depth dissection and fast cytological examination of the sample . Results The success rate of the puncture about the 26 cases were 100% . The accuracy and false negative rate of the puncture biopsy were 92.3%(24/26) . The produced rate of the complication after puncture were 0%(0/26) .Conclusion CT-guided muscleorskeleton tumor puncture biopsy with the co-axle technique ,can selected many times and points . Improved the positive rate and the accuracy rate ,reduced the produced rate of the complication . It is a easy technique . It is a safer and efficacious diagnose measure .
Keywords:CT-guided  The co-axle technique  Muscleorskeleton tumor  Puncture biopsy