工作场所空气中氢化锗的原子荧光测定法
作者姓名:Zhang J  Tao X  Li CL  Yan HF
作者单位:中国疾病预防控制中心职业卫生与中毒控制所,北京,100050
基金项目:卫生部卫生行业科研专项:职业卫生监测与健康监护技术研究
摘    要:目的 建立工作场所空气中氢化锗原子荧光测定方法.方法 活性炭管采样,硝酸解吸过滤,原子荧光光谱仪检测.结果 浓度在0.85~300.00 μg/L范围内线性关系良好,相关系数r=0.9993;最低检出限和最低检出浓度为0.51 μg/L和0.000 17 mg/m3(以采集48 L空气样品计),加标回收率为90%~106%;用相对标准偏差表示批内精密度为3.3%~5.9%,批间精密度为3.7%~6.3%.结论 该方法线性范围宽,灵敏度高,精密度好,适用于工作场所空气中氢化锗的测定.
Abstract:
Objective An atomic fluorescence (AFS) method was developed to determine germanium hydride in the air of workplace.Method Germanium hydride in the air of workplace was collected by charcoal tube,and desorbed by nitric acid followed filtration with 0.22 μm cellulose filter,the AFS was used to determine Germanium in the desorbed solution.Results The linear was good at the range of 0.85~300 μg/L with the correlation coefficient of 0.9993;the LOD and LOQ were 0.51 μg/L and 0.000 17 mg/m3,respectively.The recovery was ranged from 90% to 106%,the RSD of intra- and inter- precision were 3.3%~5.9% and 3.7%~ 6.3%.Conclusion The linear range,sensitivity and precision of the method were all satisfied for the determination of germanium hydride in the air of workplace.

关 键 词:氢化锗  原子荧光

Development of determination of germanium hydride in the air of workplace by atomic fluorescence
Zhang J,Tao X,Li CL,Yan HF.Development of determination of germanium hydride in the air of workplace by atomic fluorescence[J].Chinese Journal of Industrial Hygiene and Occupational Diseases,2011,29(6):450-451.
Authors:Zhang Jing  Tao Xue  Li Chun-Ling  Yan Hui-Fang
Institution:National Institute of Occupational Health and Poison Control, Chinese Center for Disease Control, Beijing 100050, China.
Abstract:Objective An atomic fluorescence (AFS) method was developed to determine germanium hydride in the air of workplace.Method Germanium hydride in the air of workplace was collected by charcoal tube,and desorbed by nitric acid followed filtration with 0.22 μm cellulose filter,the AFS was used to determine Germanium in the desorbed solution.Results The linear was good at the range of 0.85~300 μg/L with the correlation coefficient of 0.9993;the LOD and LOQ were 0.51 μg/L and 0.000 17 mg/m3,respectively.The recovery was ranged from 90% to 106%,the RSD of intra- and inter- precision were 3.3%~5.9% and 3.7%~ 6.3%.Conclusion The linear range,sensitivity and precision of the method were all satisfied for the determination of germanium hydride in the air of workplace.
Keywords:germanium hydride  Atomic Fluorescence