首页 | 本学科首页   官方微博 | 高级检索  
     

3D打印钛合金椎间融合器置入治疗脊髓型颈椎病的临床疗效及颈椎矢状位参数变化
引用本文:张亚,刘志维,方忠,吴巍,李锋. 3D打印钛合金椎间融合器置入治疗脊髓型颈椎病的临床疗效及颈椎矢状位参数变化[J]. 骨科, 2021, 12(2): 97-102
作者姓名:张亚  刘志维  方忠  吴巍  李锋
作者单位:华中科技大学同济医学院附属同济医院骨科,武汉430030
基金项目:国家重点研发计划(2016YFB1101300)
摘    要:目的 探讨3D打印钛合金椎间融合器(3D Cage)置入治疗脊髓型颈椎病的临床疗效及颈椎矢状位参数变化.方法 回顾性研究我院2018年7月至2020年1月收治的接受单节段颈椎前路椎间盘切除植骨融合术(anterior cervical discectomy and fusion,ACDF)的脊髓型颈椎病病人39例,按照...

关 键 词:3D打印  椎间融合器  颈椎曲度  颈椎矢状面偏移距离  T1倾斜角
收稿时间:2020-11-30

Clinical efficacy of 3D-printed titanium cage in the treatment of cervical spondylotic myelopathy and changes in cervical sagittal parameter
ZHANG Y,LIU Zhi-wei,FANG Zhong,WU Wei,LI Feng. Clinical efficacy of 3D-printed titanium cage in the treatment of cervical spondylotic myelopathy and changes in cervical sagittal parameter[J]. Orthopaedics, 2021, 12(2): 97-102
Authors:ZHANG Y  LIU Zhi-wei  FANG Zhong  WU Wei  LI Feng
Affiliation:Department of Orthopaedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
Abstract:Objective To explore the clinical efficacy of 3D-printed titanium cage(3D Cage)in the treatment of cervical spondylotic myelopathy and changes in cervical sagittal parameter.Methods A retrospective study was performed on 39 patients with cervical spondylotic myelopathy in our hospital from July2018 to January 2020,who received 1-level anterior cervical discectomy and fusion,and were divided into the 3D group(18 cases)and the conventional group(21 cases)according to the implant.The length of hospital stay,operation time and intraoperative blood loss were compared between the two groups.Japanese Orthopaedic Association scores(JOA),visual analogue scale score(VAS)as well as neck disability index(NDI)were recorded before surgery,3 days after surgery and at the last follow-up.The sagittal parameters of the cervical standing radiographs were measured including intervertebral height,C2-7 Cobb angle,C2-7 sagittal axis distance(C2-7 SVA)and T1 slope,and the clinical efficacy was evaluated.Results There were no statistically significant differences in hospital stay,operation time,intraoperative blood loss,JOA,VAS and NDI scores at last follow up between the two groups.Three days after surgery,intervertebral height,C2-7 Cobb and T1 slope were significantly increased in both groups(P<0.05).The intervertebral height and C2-7 Cobb in the 3D group were 8.7±0.8 mm,18.6°±7.5°,significantly higher than those in the conventional group(9.3±0.9 mm,20.8°±7.3°).The T1 slope(24.2°±5.4°)at the last follow-up was significantly higher than that in the conventional group(P<0.05).At the last follow-up,the intervertebral height(7.2±0.9 mm)and T1 slope(20.7°±5.0°)were significantly reduced compared with 3 days after surgery in the conventional group(P<0.05).C2-7 SVA showed no statistical difference between groups or at any time period in the same group.Conclusion 3D-printed titanium cage implantation for the treatment of cervical spondylotic myelopathy has definite clinical efficacy and advantages in maintaining the intervertebral height,cervical curvature and T1 slope.
Keywords:3D printing   Cage   Cervical curvature   Cervical sagittal axis distance   T1 slope
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《骨科》浏览原始摘要信息
点击此处可从《骨科》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号