首页 | 本学科首页   官方微博 | 高级检索  
     


Effects of ventilation on cardiac output determined by inert gas rebreathing
Authors:Damgaard Morten  Norsk Peter
Affiliation:Medical Department B, Department of Aviation Medicine, Copenhagen University Hospital, Denmark. mdamgaard@rh.dk
Abstract:One of the most important methodological problems of the foreign gas rebreathing technique is that outcome of the measurements depends on procedural variables such as rebreathing frequency (RF), rebreathing bag volume (V(reb)), lung volume at start of rebreathing and intervals between measurements. Therefore, in 10 healthy males we investigated the effects of changes in ventilation pattern on cardiac output (CO) estimated by an N(2)O-rebreathing technique. Reducing the rebreathing volume (V(reb)) from 1.5 to 1.0 l diminished CO by 0.5 +/- 0.2 l min(-1), whereas an increase in V(reb) from 1.5 to 2.5 l had no effects. CO was 1.0 +/- 0.2 l min(-1) higher when, rebreathing was performed after a forced expiration than following a normal tidal expiration. Serial determinations of CO required a 3-min interval between the measurements to avoid effects of recirculation of N(2)O. Changing RF from 15 to 30 breaths min(-1) or adding serial dead space by up to 600 ml did not affect the determination of CO. In conclusion, the rebreathing procedure for determination of CO at rest should be performed following a normal tidal expiration with a rebreathing bag volume of between 1.5 and 2.5 l and with manoeuvres separated by at least 3-5 min. Variations in RF within the physiological range from 15 to 30 breaths min(-1) do not affect outcome of the measurements.
Keywords:breathing frequency  hyperventilation  oxygen uptake  pulmonary blood flow  respiratory dead space
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号