Prediction and Assessment of Flammability Hazards Associated with Metered-Dose Inhalers Containing Flammable Propellants
Authors:Dalby  Richard N
Institution:(1) Department of Pharmacy and Pharmaceutics, Medical College of Virginia/VCU, The Aerosol Research Group, Richmond, Virginia, 23298
Abstract:Several potential replacements for chlorofluorocarbons (CFCs) in metered-dose inhalers (MDIs) are flammable. The flammability hazard associated with their use was assessed using a range of MDIs containing 0–100% (w/w) n-butane (flammable) in HFC-134a (nonflammable) fitted with either 25-, 63-, or 100-µl metering valves or continuous valves. In flame projection tests each MDI was fired horizontally into a flame, and the ignited flume length emitted from the MDI was measured. Flame projections of ge60 cm were produced by all formulations fitted with continuous valves which contained ge40% (w/w) n-butane in HFC-134a. Using metering valves the maximum flame projection obtained was 30 cm. This was observed with a formulation containing 90% (w/w) n-butane in HFC-134a and a 100-µl valve. For a particular formulation, smaller metering valves produced shorter flame projections. Because many MDIs are used in conjunction with extension devices, the likelihood of accidental propellant vapor ignition was determined in Nebuhaler and Inspirease reservoirs and a Breathancer spacer. Ignition was predictable based on propellant composition, metered volume, number of actuations, and spacer capacity. Calculated n-butane concentrations in excess of the lower flammability limit LFL; 1.9% (v/v)] but below the upper flammability limit UFL; 8.5% (v/v)] were usually predictive of flammability following ignition by a glowing nichrome wire mounted inside the extension device. No ignition was predicted or observed following one or two 25-µl actuations of 100% n-butane into large volume Nebuhaler (750 ml) or Inspirease (660 ml) devices. Additionally, several other formulations containing lower proportions of n-butane also remained nonflammable, due to failure to reach the LFL. In the small-volume Breathancer spacer (140 ml), nonflammability was usually due to n-butane exceeding its UFL. In this situation further dilution during respiration could result in a flammable mixture. Using a carefully selected propellant blend, metering volume, and spacer design, environmentally acceptable flammable propellants may have considerable utility in MDIs reformulated without CFCs.
Keywords:metered-dose inhaler (MDI)  aerosol  formulation  flammability  propellant  spacer  reservoir
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号