Detection of antibodies to human immunodeficiency virus type 2 (HIV-2) in blood donor sera using United States assay methods for anti-HIV type 1 |
| |
Authors: | K Sazama, IK Kuramoto, PV Holland, AM Courouce, D Gallo, CV Hanson |
| |
Affiliation: | Sacramento Medical Foundation Center for Blood Research, California. |
| |
Abstract: | Twelve serum samples from French blood donors that were uniformly reactive in tests for antibody to human immunodeficiency virus type 2 (anti-HIV-2) also were reactive in 92 to 100 percent of tests with three anti-HIV type 1 (anti-HIV-1) enzyme-linked immunoassays currently in widespread use for donor screening in the United States. Supplemental tests for anti-HIV-1 on these anti-HIV-2-reactive samples differed in their responses. All samples reacted in a licensed anti-HIV-1 Western blot, but there was an atypical band near the p41 position, which could be a clue to the fact that this result was a cross-reaction with anti-HIV-2. A recombinant immunoblot gave an indeterminate result for anti-HIV-1 in all 12 samples. A local immunofluorescence assay for anti-HIV-1 reacted with 92 percent of the samples, but a commercial one detected only 58 percent. |
| |